Scope of Work

ATC Associates, Inc. (ATC) was retained by New York City Boarv of Education (NYC- BOE) to collect dust wipes to be analyzec for lead content. Du;>t wipe samples were collected from areas recommended by the NYC- BOE. These areas are the following:

• First floor lobby • Cafeteria • Auditorium • Two randomly selected classrooms per floor • Hallways-one sample per floor

The purpose of the dust wipe sampling is to determine if dust in the school contains lead. ATC’s representative Mr. Herant Antonyan visited P.S. 2M locateci at 122 Henry Street, New York, NY on August 23, 2002. Dust wipes to be analyzed Tor lead content were collected from the aforementioned areas indicated by the New York City Board of Education Environmental Health & Safety L nit and in accordance w ith HUD protocols.

LEAD-IN-DUST SAMPLING

Lead-in-dust threshold levels The New York City Health Code, part 173.14 and the Federal Departments of Housing and Urban Development (HUD) and Environmental Protection Agency (LPA) have established acceptable lead-in-dust levels for re-occupancy after a lead abatement has occurred (commonly referred to as “final clearance” levels). As stated in the Code, final clearance after abatement has taken place is achieved when dust wipe samples indicate lead levels below those listed below:

For Windowsills: 250 pg/ft- For Floors: 40 pg/ft^

Although the lead-in-dust samples collected at P.S. 2M were not collected in response to lead abatement, the same thresholds are used since no other regula;ions or standards are applicable to this project.

Sampling Methodology ATC provided all laboratory analytical serx'ices in support of this limited inspection. ATC is certified by the New York State Department of Health’s Envi onmental Laboratory Accreditation Program to perform lead and related analyses of environmental samples (Laboratory ID Number: 10879). The laboratory utilizes the United States Environmental Protection Agency analysis method numbei- SW846-7420 and the National Institute of Occupational Safety and Health method number 7082M.

The lead-in-dust samples were obtained by gently wiping a pre-measured surface area with non-alcohol moistened towelettes. ATC’s representative wore disposable gloves; a P.S. 2M (Satc • t gocI A t e « I HC August 26, 2002

CITY_21MC1OO_OO6729198

NYC-WTC_000199392

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000199392Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →