Scope of Work

ATC Associates, Inc. (ATC) was retained by New York City Board of Education (NYC- BOE) to collect dust wipes to be analyzed for lead content. Dust wipe samples were collected from areas recommended by the NYC- BOE. These areas are the following;

• First floor lobby • Cafeteria • Auditorium • Two randomly selected classrooms per floor ■ • Hallways-one sample per floor

The purpose of the dust wipe sampling is to determine if dust in the school contains lead. ATC’s representative Mr. Herant Antonyan visited P.S. 126M & M893 located at 80 Catherine Street, New York, NY on August 21,2002. Dust wipes to be analyzed for lead content were collected from the aforementioned areas indicated by the New York City Board of Education Environmental Health & Safety Unit and in accordance with HUD protocols. S' LEAD-IN-DUST SAMPLING

Lead-in-dust threshold levels The New York City Health Code, part 173.14 and the Federal Departments of Housing and Urban Development (HUD) and Environmental Protection Agency (EPA) have established acceptable lead-in-dust. levels for re-occupancy after a lead abatement has occurred (commonly referred to as “final clearance” levels). As stated in the Code, final clearance after abatement has taken place is achieved when dust wipe samples indicate lead levels below those listed below;

For Windowsills: 250 gg/tf For Floors: 40 gg/tf

Although the lead-in-dust samples collected at P.S. 126M & M893 were not collected in response to lead abatement, the same thresholds are used since no other regulations or standards are applicable to this project.

Sampling Methodology ATC provided all laboratory analytical services in support of this limited inspection. ATC is certified by the New York State Department of Health’s Environmental Laboratory Accreditation Program to perform lead and related analyses of environmental samples (Laboratory ID Number: 10879). The laboratory utilizes the United States Environmental Protection Agency analysis method number SW846-7420 and the National Institute of Occupational Safety and Health method number 7082M.

P.S. J26M& M893 CVATC *cao CIAI t « IBC . August 22. 2002

CONFIDENTIAL, CITY_2IMCl00_003430856 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000175258

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000175258Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →