104 East 25th Street New York. New York 10010 www.atc-enviro.com 212.353.8280 Fax 212.353.8306 ASSOCIATES INC.

December 17, 2001

Mr. Bernard P. Orlan Director, Environmental Health and Safety New York City Board of Education 28-11 Queens Plaza North Long Island City, NY 11101

Re: Air Sampling for Metals Stuyvesant High School ATC Project No. 15-19125-0246

Dear Mr. Orlan:

ATC Associates, Inc. (ATC) is pleased to provide this letter report of air sampling for metals in airborne dust on December 3, 2001, at the referenced school. The New York City Board of Education (BOE) requested this sampling at the recommendation of H. A. Bader, a consultant retained by the parents association.

ATC collected three (3) samples for metals at specified locations. Samples were collected for a minimum of seven (7) hours using 37 mm mixed cellulose ester filter connected to battery- powered sampling pumps at a flow rate of 2 liters per minute. Pumps were calibrated before and after each sampling period. Two (2) samples were collected inside the building and one (1) was collected on the roof. One blank sample was also submitted on each day. The samples were sent to PSC Analytical Services, Inc., an American Industrial Hygiene Association-accredited laboratory in Reading, PA. Analysis was performed by NIOSH Methods 7300M. Each sample was analyzed for a panel of eleven (11) metals. The metals were aluminum (Al), cadmium (Cd), chromium (Cr), cobalt (Co), copper (Cu), iron (Fe), magnesium (Mg), manganese (Mn), molybdenum (Mo), nickel (Ni) and zinc (Zn). A copy of the analytical report is attached.

The sampling locations, specified by the parents association consultant, were as follows: • floor lobby; • 2”“* floor bridge entrance hallway; • Roof (southeast).

The established regulatory values for metals are intended for industrial workplace exposures and are not generally applicable to office/school settings. There are no standards for these metals in indoor air in non-industrial situations.

SAMPLE RESULTS

The only metal present at concentrations greater than the limits of detection was chromium.

The concentrations indoors were 0.000349 mg/m^ and 0.000309 mg'mY The outdoor (roof) sample contained 0.000346 mg/m^ The blank contained detectable chromium (0.261 micrograms) as well. After the blank is subtracted, the indoor samples contained 0.000077 and 0.000038 mg/m' and the outdoor sample contained 0.000074 mg/m\

CITY_21MC100_003046839

NYC-WTC_000197647

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000197647Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →