NYC Law Department release
Independent mirror · updated as the City releases more · v1.3.2
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 2 pages

NYC-WTC_000196919

Label derived from the City's folder field. The City does not supply document titles.NYC-WTC_000196919–000196920
Page image
Scanned page image, NYC-WTC_000196920
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Mr. Bernard P. Orlan April 16, 2002 Respirable Particulate Monitoring Page 2 Various Locations/Manhattan ATC Project No. 15-19125-0314

TARGET GUIDELINES FOR AIR QUALITY PARAMETERS EVALUATED* ^Tiyi

Respirable 65 micrograms per cubic Particulates meter of air (gg/m^) 24 USEPA NPAAQS (PM2.5) hour average Respirable USEPA recommendation Particulates 40 24 hour average for children/sensitive (PM2.5) individuals USEPA = United States Environmental Protection Agency NPAAQS = National Primary Ambient-Air Quality Standard

REAL-TIME SAMPLING RESULTS

Twenty-nine (29) indoor and thirty-one (31) outdoor respirable particulates measurements* were collected from twenty-nine school locations in Manhattan, ranging from West 11*^ Street to East 33"^ Street. The measurements were made from 5:50 A.M. to 5:25 P.M. The lAQ field report forms are provided as the Attachment.

The outdoor PM2.5 concentrations ranged from 32 gg/m^ to 63 pg/m^. The indoor concentrations ranged from 9 pg/m^ to 52 pg/m^. None of the indoor or outdoor readings were above the NPAAQS of 65 pg/m^. Twenty-one (21) of the outdoor measurements and eight (8) of the indoor measurements were above the EPA recommended guideline for children and sensitive individuals of 40 Mg/ni3.

* These measurements were instantaneous readings, the NPAAQS and the recommendation for children are 24-hour averages.

CONCLUSION

Based on our measurements, none of the indoor or outdoor readings were above the NPAAQS of 65 pg/m^. Twenty-one (21) of the outdoor and eight (8) of the indoor measurements were above the EPA recommended guideline for children and sensitive individuals of 40 pg/m3.

It is our pleasure to provide these air quality consultative services to the New York City Board of Education. If you have any questions about this report, please call (212) 353-8280, extension 212 or 211.

Sincerely, ATC ASSOCIATES Rgyie'Wfed by 'V • / / Yiannis Efstathiou ■James R. Cohn, CIH, CSP / Senior Project Manager Regional Manager, Industrial Hygiene Division

Attachment

CITY_21MC100_003044041

NYC-WTC_000196920

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000196920Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →