Mr. Bernard P. Orlan February 8, 2002 Respirable Particulate Monitoring Page 2 Various Locations/Manhattan ATC Project No. 15-19125-0314

TARGET GUIDELINES FOR AIR QUALITY PARAMETERS EVALUATED* PARA& TARGET 1 VEL AGENCY OR ill ORGANIZATION Respirable 65 micrograms per cubic Particulates meter of air (gg/mS) 24 USEPA NPAAQS (PM2.5) hour average Respirable USEPA recommendation Particulates 40 gg/m^ 24 hour average for children/sensitive (PM2.5) individuals USEPA = United States Environmental Protection Agency NPAAQS = National Primary Ambient-Air Quality Standard

REAL-TIME SAMPLING RESULTS

A total of fifty-eight (58) outdoor respirable particulates measurements* were collected from twenty-nine locations in Manhattan, ranging from W. 11th st. to E. 33th St. The measurements were made from 7:30 A.M. to 4:35 P.M. The lAQ field report forms are provided as the Attachment.

The outdoor PM2.5 concentrations ranged from 28 gg/m^ to 85 gg/m-’. The indoor concentrations ranged from 11 gg/m^ to 44 gg/m-. Two (2) outdoor readings were above the NPAAQS of 65 gg/m^. One (1) of the indoor and sixteen (16) of the outdoor measurements were above the EPA recommended guideline for children and sensitive individuals of 40 gg/jn^.

• These measurements were instantaneous readings, the NPAAQS and the recommendation for children are 24-hour averages.

CONCLUSION

Based on our measurements, none of the indoor and two (2) of the outdoor readings were above the NPAAQS of 65 gg/m^. One (1) of the indoor and sixteen (16) of the outdoor measurements were above the EPA recommended guideline for children and sensitive individuals of 40 gg/m".

It is our pleasure to provide these air quality consultative services to the New York City Board of Education. If you have any questions about this report, please call (212) 353-8280, extension 212 or 261.

Sincerely, ATC ASSOCIATES INC.

Yiannis Efstathlou James R. Cohn, CIH, CSP Project Manager Regional Manager, Industrial Hygiene Division

CITY_21MC100_003020799

NYC-WTC_000208201

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000208201Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →