ATC Associates 104 East 25 Street, New York, NY 10010 Phone: (212) 353-8280 Fax; (212) 353-8306
Attn: Mr. Bernard Orlan Received: 11/15/01 9:00:00 PM ■ N.Y.C. Board of Education 28-11 Queens Plaza North ATC Group#: 5897 Long Island City, NY 11101 Analysis Date: 11/15/01 Fax: (212) 475-4122 Phone: (212)477-8941 Project: New Stuyvesanl H. S. , 345 Chambers St., NY , NY Exterior and Interior of Building and Roof
Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) Performed by EPA 40 CFR Part 763 Final Rule (AHERA) Analytical Asbestos 4rca Non '^^bestos Structures Sensitivity Concentration Sample Volume Analyzed Asb 0.5fi-5 Sft (S/cc) (S/mmO (S/cc) Notes 1 1936.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 5897 -1
2 1936.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 5897 -2
3 1936.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 5897 -3
4 1936.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 5897 -4
5 1944.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 5897 -5
6 1944.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 5897 -6
7 1936.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 5897 -7
8 1928.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 5897 -8
MICHAEL GORYCKI MICHAEL A. GORYGKI, Ph.D.
Analyzed by. Approved by.
Disclaimer; The laboratory is not responsible tor data reported in structures/cc, which is dependent on volume collected by non-laboratory personnel. This lab Is only responsible for data reported in structures/mmT This report may not be reproduced, except in full, without written approval by ATC Associates Inc. This report may not be used to claim product endorsement by NVIAP or any other agency of the U.S. Government This reports relates only to the samples reported above. Quality control data (including 95% i confidence limits and laboratory and analysis’ accuracy and precision) is available upon request
j Accredited tor NVLAP PLMATEM #101187-0, NY State ELAP #10879
CITY_21MC100_003083243
NYC-WTC_000188965
OCR can misread numbers and units. Confirm readings against the page image before using them.
Related records
Browse subjects →Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
Same-box records
7 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗7 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗7 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗7 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000184589
Formal laboratory report from ATC Associates detailing TEM asbestos fiber analysis results for a high school building on June 3, 2002.
7 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000179486
Laboratory report documenting transmission electron microscopy asbestos fiber analysis for a high school project received April 11, 2002.
7 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗7 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗7 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗7 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗7 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗7 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗Filed elsewhere
No available related records indexed in this group.
More like this page
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000184278
Formal laboratory report detailing transmission electron microscopy results for exterior and interior air samples from a New York City Board of Education high school.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Others also read
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
Similar indexed content
Similar indexed content
Similar indexed content
Similar indexed content
Similar indexed content