NYC Law Department release
Independent mirror · updated as the City releases more · v1.3.2
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 2 pages

NYC-WTC_000187106

Label derived from the City's folder field. The City does not supply document titles.NYC-WTC_000187106–000187107
Page image
Scanned page image, NYC-WTC_000187106
OCR text

OCR status: ocr · source: ours

NYC 9/11 Public Portal Document 228 East 45th Street New York, NY 10017 (212) 922-0077 Fax (212) 922-0630 WARREN & PANZER ENGINEERS, P. C. PAGE 1 OF 1. AIR MONITORING LOG SHEET/CHAIN-OF-CUSTODY FORM 24 hrt/a 12 hrt/a 6 hrt/a 3 hrt/a Immediate t/a P.O. WaP FILE #: 1079.01.02 PROJECT: CLENT NYC. DE I RoaF Ceanig ANALYSISNMIHUD DEP-sau NABPFAEDAY: WARREN avd PaNZeR. CONTACT. MR. M. NoLaN. LOCATION: 16| kaupistNY. N PCM TEM RooF oF 184FLOOR. circle one 7400 AHERA EPA LEVEL II TECHNICIAN: YURy Bedin. SAMPLE SAMPLE SAMPLE PUMP FLOWRATE TIME NUMBER DESCRIPTION/LOCATION TYPE # START STOP 1 IWA. on Roof. CenteR of WorkARce. 3 3.0 3,0 2IWA. on Roof. South.Sectron oFw.A. 3 3.0 3.0 3IWA.ankoof. NorthocctianoFW.h 3.0 3.0 3.0 3.0 3.0 3.0 ON OFF 9:15 17:15 9:17 17:17 9:19 17:19 9:21 17:21 9:23 17:23 TOTAL TIME 480 480 480 480 480 VOLUME CONCENTR (liters) (fib./cc.) 1440 1440 1440 1440 1440 7 - 8 - Ticld BlaNk- S. Blank— COMMENTS: CITY 21MC100 002951254 SAMPLE BY: SIGNATURE: _ RELEASED BY: SIGNATURE: RECEIVED BY: SIGNATURE: _ YuRy BedrN. DATE: 10-11-02. 702-10-070 Yuaul Beei. DATE: 10-11-02. SAMPLE TYPE CODES Uurd Bedin. Released 18:36PM 1 - Blank 5 - Final Clearance (inside) CAJGA • 2 - Pre-Abatement 6 - Final Clearance (outside) DATE: 10/12/02 3 - During Abatement 7 - Personal Lajiy 4 - During Glove Bag Removal 8 - Background SEE REVERSE SIDE FOR ANALYSIS INFORMATION NYC-WTC_000187106

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000187106Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000186911

Partial air monitoring log sheet and chain-of-custody form for asbestos analysis by Warren & Panzer Engineers.

Similar indexed content

Compare copies and versions →