Site: WTC NYC (WTC) WA#:
Tetra Tech Christopher Jimenez WAM Neil Norrell/Chris Jimenez
Contact:
Phone: Phone: 212-608-7097
Sample # i 07590 07591 07592 07593 ;07594
i Location ! Washing Tent Austin Tobin Plaza South Tower North T ower South Tower #2
I Pump/Sampler#
]___ —___ r
I Media I Tedlar Bag Tedlar Bag : Tedlar Bag Tedlar Bag Tedlar Bag
i---- '-----------
I Analysis / Method VOCs VOCs [vocs VOCs VOCs
1 Time/Date (Start) 09:00/0 03/13/02 09:20/0 03/13/02 *09:42/0 03/13/02 09:28/0 03/13/02 11:50/0 03/13/02
..—- ---------------—_—.—_------------
Time/Date (Stop) 09:00/1 03/13/02 I 09:20/1 03/13/02 j 09:42/1 03/13/02 09:28/1 03/13/02 I 11:50/1 03/13/02
Total Time (Minutes) 1 (min) 1 (min) j 1 (min) 1 (min) 1 (min)
Pump Fault N N IN !N N
Flow rate/min (Start) 1.0 Liters 1.0 Liters 1.0 Liters ; 1.0 Liters ' 1.0 Liters
Flow rate/min (Stop) 11.0 Liters 1.0 Liters 1.0 Liters 11.0 Liters 1.0 Liters
j Flow rate/min (Avg) 1.0 Liters 1.0 Liters i 1.0 Liters 1.0 Liters 1.0 Liters
I Volume jl.OO Liters ! 1.00 Liters i 1.00 Liters 1.00 Liters {1.00 Liters
I------- ------------------
1
I Comments:
07590:
0759T. Breathing zone sample. No plume
07592: Sample taken at ground level, from plume
I 07593: Sample taken from ground level, No Plume
j 07594: sample taken at ground level, from plume