OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

We hereby certify that the test results presented here are accurate and confomi to the reported grade specification. o SMI Steel - Alabama o P.O. Box 321188 CERTIFIED MILL TEST REPORT o I Binningham, AL 35232-1188 For additional copies call CkAtsttKt SUukCUUkriL o

(205) 592-8981 (800) 621-0262 U Quality Assurance Manager

HEAT NO.; J13582 SECTION; S O CERTIFIED STEEL S H CERTIFIED STEEL SHIP#; BOL#: 100614/42 e' F 5x1/4 x20'0" L 1333 BRUNSWICK PIKE. SUITE 200 I 199 WHITEHEAD ROAD 146791 u F 127X6.4x6.096 D LAWRENCE. NJ 08648- P TRENTON. NJ 08619- INV#: 8300245382 GRADE; ASTM A36-00 CUSTPO#: 011086 T T ASTM A36M-00 0 0 CUSTP/N:

CHEMICAL ANALYSIS PROPERTIES % MECHANICAL _ _________ TESTI ___________ TEST 2 TEST 3 c 0.14 IMPERIAL METRIC IMPERIAL METRIC IMPERIAL METRIC Mn 0.63 Yield Strength 48.8 KSI 336.5 MPA 48.8 KSI 336.5 MPA P 0.009 Tensile Strength 70.4 KSI 485.4 MPA 71.0 KSI 489.5 MPA S 0.034 Elongation 36 X 36 X 38 X 38 X Si 0.22 Gauge Length 8 INS 203 MM 8 INS 203 MM Cu 0.26 Reduction of Area Cr 0.14 Bend Test Ni 0.14 Diameter Mo 0.057 Charpy Impact Cb 0.001 Test Temp V 0.002 Sample Size Sn 0.010 Orientation B 0.0000 Hardness Ti 0.001 C.Eq 0.31 N 0.0094 JOMINY RESULTS - Rockwell C hardness at 1/16th inch Increments GRAIN SIZE INCLUSION RATING 1 2 3 4 5 6 7 8 9 10 11 12 METHOD METHOD

TYPE 13 14 15 16 18 20 22 24 26 28 30 32 RESULT

SIZE

100% MELTED AND MANUFACTURED IN THE USA AND FREE OF MERCURY CONTAMINATION IN THE PROCESS REMARKS:

AUG-31-2001 11:01 Page 1 OF 1

NYC-WTC_000186524

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000186524Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →