TEM Asbestos (air) Count Sheet Client .Name: NYC BOE Volume (liters): 1816 Lab Group #: 6990 Filter Type / Filter Area: MCE 385 mm- Lab Sample #: 9 Grid Opening Size: 0.01124

Client Sample #: 05 Area Examined: 0.04496 mrn-

GRID BOX: Mannification: 20,000 GRID ID: Accelerating V oltage: 100 KeV # Grid Openings: 4 Analysis Date: 3/9/02

■Analysis Performed By: MARK PEYSAKHOV

GO Structure Structure Type Length ID of Structure Nor 7 EDS (Nonadb I No F B C M >=05 p >=5|j Chrys Amphibole Nonasfc Ambig/ND No Coord Elements)

n —h

J---

Struct = ■> U 5li >5tl Aspect R.itio Grid acceptance

7 = Positive diffraction pattern properties conforming to <50% undissolved [liter, overlapped or folded Totals <10% particulate coverage >50% coverage ate laboratory identification criteria obsen/ed least 20 unfolded or overlapped grid sguares <5% 0 F I B I C i M ! >5u 7= EDS spectrum conforming to 'lacoratoiy' noies or opaque areas . Identification criteria observed Chrysotile amphiboles Amphibole F = Single Fiber Amosite B = Bundle (<3 fibers <1 fiber diameter apart Crocidolite Ambiguous C = Cluster (>3 Intersections) Anthophyllite Non-Asbestos i Tremolite M = Matrix Actinolite J Non-Identified USD = No Structures Delected

CITY_21MC100_003102377

NYC-WTC_000183278

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000183278Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →