TEM Asbestos air sample results, NYC BOE, Mar 2002

Machine-extracted title · confidence 95%

Laboratory report documenting transmission electron microscopy analysis of an air sample collected by the NYC Board of Education on March 6, 2002.

NYC-WTC_000183235
Page image
Scanned page image, NYC-WTC_000183235
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

TEM Asbestos (air) Count Sheet Client Name: NYC BOE Volume (liters): 1816 Lab Group #: 6943 Filter Type / Filter Area: MCE 385 mm^ Lab Sample #: 12 Grid Opening Size: 0.01124

Client Sample #: 15 Area Examined: 0.04496 mm'

GRID BOX: Maanification: 20,000 GRID ID: Accelerating Voltage: too KeV # Grid Openings: 4 Analysis Date: 3/6/02

Analysis Performed By: MARK PEYSAKHOV

GO Structure Structure Type Length IC of Structure N or EDS (Nonadb , No F B C M >=05 p >=r5(J Chry^ Amphibole Nonasb Arrbig/ND No Coord <5p Elements) !

a

U4

Struct = > 0.5p >5:1 Aspect Ratio Grid acceptance

/= Positive diffraction pattern properties conforming to <50% undissolved filter, overlapped or folded T^ls <19% particulate coverage >50% coverage ate aboraton/ identification criteria obsei^ed least 20 unfoldea or overlaopeo grid squares <5% !______________ I F 1 B j C 1 M 1 >: EDS spectrum confoiming to laboratory holes orooaque areas dentirication criteria ooserved Chrysotile AMPHIBOLES Amphibole : - = S ngle Fiber Amosite S = Bundle (<3 fibers <1 fiber diameter apart Crocidolite i Ambiguous 1 D = Cluster (>3 Intersections) Anthophyllite Non-Asbestos j Tremolite M = Matrix Actinolite Non-Identified ) NED = Mo Structures Delected

CITY_21MC100_003102312

NYC-WTC_000183235

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000183235Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →