NYC Law Department release
Independent mirror · updated as the City releases more · v1.3.2
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

Asbestos TEM analysis results, Oct 2001

Machine-extracted title · confidence 95%

Laboratory transmission electron microscopy report documenting the analysis of a bulk air sample for asbestos fibers.

NYC-WTC_000182539
Page image
Scanned page image, NYC-WTC_000182539
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC ASSOCIATES INC. TEM ANALYSIS LAS GROUP »; 563S - 10/08/01 Lab Sample No. 60557 Filter Type MCE 25 mm Operator 1''^ Client Spl. No. NSHA-EB&R-10/8-02 Filter Area 385 mm 2 Instrumenc I.D. EM 10 CRX Grid I.D. Disk No. Screen Magnification 16,400X (GO) Area 0.01124 mm"2 Comments Acc. Voltage 80 kV No. GO to be Analysed _4 ( 3.147 Struct. Corspd. to 70 5/mm^2.)

GO. Structure Structure Type Length I.D. of Structure EDS >0.5 um (Nonasb. No Coord. No. F B C M > Sum Chrys. Amphibole Nonasb. Ambig./ND Elements) < 5 um

3^

3

Store all unrepeated spectra—^ Photo No. (from I in fl aabestos- Identify all atructurea uaing EDS Check diffraction for aabeatoa containing samples) Grid acceptance; I istructures up to 70a/iftrT (l»t 4) <50X undioBolvcdTITTer? , overlapped or folded Struct. = > 0.5um A > 3:1 Aspect Ratio <10X particulate coverage >50X coverage Na Not Observed (EDS spectrum or diffraction pattern) at least 20 unfolded or overlapped grid squares Totals y/a Positive diffraction pattern properties conforming <5X holes or opaque areaa F B C M Sum to laboratory Identification crlloria observed. Inused porUon For chrynlile: 0.73nm apaeinx for (020) rsnecUons, or niter 0.93nm spacing for Uis layer Iios repeat, streaking Chrysotile of (HO) and (130) reflecUona. Avoided portion of niUr Por amphiboles: a.&3nm layer Hoe repeat, and approx. PorUon of niter (2mm vide) 3.3 raUo of non-lwinned layer Une spot spacing to ■ubject to •saminaUoa Amphibole layer line repeat distance (0.Sanm). \Za BDS spectrum conforming to laboratory identification criteria observed. AMPHIBOLES Ambiguous P= Slnfle Fiber (1-3 InLerscctioni s 1-3 fibers) Ainoaite Bs Bundle (>3 fibers <1 fiber diameter apart) C= Cluster (>3 inUrsecUoni) 29mm flltar Crocidolite Non-asbestos I I stopping Rule»; L—_ Anthophyllite M= Matrix NSDs No Structures Detected >30 b/G.O. or la I at 4 C.O. Tremolite Actinolite Non-Identified UXDATAXPRrVATEXmKECXCADWTBXa B/22/Sa

CITY_21MC100_003099273

NYC-WTC_000182539

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000182539Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

TEM air analysis results, Oct 16 2001

NYC-WTC_000182559

Laboratory report documenting transmission electron microscopy analysis of air samples collected on October 16, 2001.

Similar indexed content

Compare copies and versions →