NYC 9/11 Public Portal Document
DEPARTMENT OF CITYWIDE ADMINISTRATIVE SERVICES
DIVISION OF FACILITIES MANAGEMENT AND CONSTRUCTION
MUNICIPAL BUILDING, 16th Floor
NEW YORK, N.Y. 10007
(212) 669-2670 Fax: (212)669-2780
E-Mail: [email protected]
WILLIAM J. DIAMOND SCOTT C. CANTONE JOSEPH WAGNER, P.E.
Commissioner Firs t Deputy Cottuttissioner Deputy Commissioner/ChiefEngineer
Court Square Building - 2 Lafayette Street, New York, NY
After the catastrophic event at the World Trade Center, the Division of Facilities Management
and Construction, Environmental Services, conducted extensive environmental surveys, collected
v^dpe samples and monitored the air.
The dust samples were collected from various floors and were analyzed under the Polarized Light
Microscopy (PLM) method. Ten percent (10%) of these samples were also analyzed under the
Transmission Electron Microscopy (TEM) method. Both methods are described in the Federal
guideline number 40 CFR Part 763, subpart F, appendix A, of the National Emissions Standard
for Hazardous Air Pollutants (NESHAP) and in 40 CPR part 763, subpart E appendix A.
The building’s air was monitored and analyzed under Phase Contrast Microscopy (PCM)
method; in accordance with Federal regulations of the National Institute for Occupational Safety
and Health (NIOSH) Method 7400.
All dust and air samples collected were analyzed at ICAM Consultant Laboratory. No asbestos
presence was detected in either the dust or the air samples.
The Official New Yoik City Web Site
nyc.gciv
CITY_21MC1OO_OO62624O8
NYC-WTC_000182331