Bulk sample analysis report for building materials, September 2001

Machine-extracted title · confidence 95%

Laboratory report detailing bulk sample analysis results for materials collected from various rooms in a Manhattan building.

NYC-WTC_000182317–000182323
Page image
Scanned page image, NYC-WTC_000182317
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

KAM(X]N$(Jl]ANTS 35-40 36th Street Long Island City New York. t1106 Tel: (718) 729-1937 Fax:(718)729.1876

BULK SAMPLE ANALYSIS REPORT CLIENT: NYC-DCAS BUILDING ADDRESS: 1 Centre Street, Manhattan, NY PROJECT#: Client Sample ID# : 1 2 3 4 5 Lab Sample ID# : 010920A-1243 010920A-1244 ()10920A-1245 010920A-1246 010920A-1247 Sample Location: Die Office Room # 2002 Room #2015 Men's Bathroom Conference Room 20th Floor South 20th Floor Scuth East 20th Floor 20th Floor 20th Floor Room B Window Homogeneity: Yes Yes Yes Yes Yes Sample Description: A/C Vent A/C Vent .AC Vent Window Sill Desk Wipe Wipe Wipe Wipe Wipe

Color; Blk Blk Blk Blk Blk Texture: Mixed Mixed Mixed Mixed Mixed Sample Treatment: None None None None None W Asbestos Present: (Type & Percent) ND ND ND ND ND Total Percent Asbestos: 0% 0% 0% 0% 0% Other Fibr. Mat. (Type & Percent): 3%CELL 3%SYNTH 2%SYNTH 1%CELL 4%CELL <1%FBGL <1%FBGL <1%FBGL 5%SYNTH Non Fibr. Mat. (Percent): 96% 97% 97% 98% 91% Date Received: 9/20/01 Date of Analysis: 9/20/01 Date of Report:

Analyst? 9/20/01

Roody I^uis Lab Manager: 1^ David Chen * Analysis of samples is performed byj*61arized Light Microscopy (PLMI - Point Counting Method 1 (EPA 600/M4-82-020) '* Analytical equipments: Stereelfmocular microscope (MEIJI EMT-Serial # 25930), Polarized Light Microscope (MEIJI ML-POL-Serial # ^034) * PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos-containing Samples will be stored for ninety (90) days and then returned to the client upon request * The results relate only to the items calibrated or tested. * The certificate of report shall not be reproduced without the written approval of the laboratory. * The report must not be used by the client to claim endorsement by NVLAP or any agency of the US Government. NYS-DOHELAP# 11273 NJST-NVLAP# 16'2047 AIHA#: 100269

1

CITY_21MC100_006262231 NYC-VVTC_000182317

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000182317Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →