World Trade Center Indoor Dust Cleaning Program Cleaning Contract WTC-ARA, WTC-ARB, WTC-ARC, WTC-ARD

August 21, 2002

ADDENDUM #2

Scope of Work for World Trade Center Indoor Dust Cleaning Program is amended as follows:

Page 2, Section B Roles and Responsiblilities, Paragraph 2 An Independent monitoring Contractor will perform DELETE

Page 2, Section B. Roles and Responsiblilities, #6. Personal Air Monitoring - DELETE

Page 4, Section D. Specifications ADD

Personal air monitoring shall be performed by the Cleaning Contractor in accordance with US DOL OSHA requirements. Personal air monitoring will be performed on a minimum of one employee of the Cleaning Contractor per shift per residence during for the first 6 weeks of cleaning operations. This may be extended based on a determination made by EPA and OSHA. Thereafter personal air monitoring samples will be taken at one sample per day. Air samples will be collected in accordance with the procedures specified in NIOSH 7400 Method and analyzed by phased contrast microscopy (PCM) followed by Asbestos Hazard Emergency Response Act (AHERA) transmission electron microscopy (TEM). Analysis of these samples shall be the responsibility of the Cleaning Contractor. Results of analysis shall be provided to EPA by the Cleaning Contractor in an approved electronic format within 24 hours of collection. Copies of the results shall also be sent immediately to OSHA and the Monitoring Contractor. The Cleaning Contractor will make these results available to the employees or their designated representatives for their review in accordance with 29 CFR 1910.1020 and 29 CFR 1926.1101.

CITY_21MC100_001569257 NYC-WTC_000182202

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000182202Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000140300 · Box DEP Box 05

Scope of work detailing evaluation procedures for HVAC systems to assess World Trade Center dust impact and cleaning recommendations.

Similar indexed content

Compare copies and versions →