3 shared non-person entities · 1 shared topics · similarity 0.952
machine-extracted · confidence unavailable · Check page ↗Asbestos analysis chain of custody, Barclay Street, July 2013
Machine-extracted title · confidence 95%Chain of custody form for asbestos analysis samples collected at 10493/101 Barclay Street on July 26, 2013.
NYC-WTC_000181895–000181898
OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
EMSL Order; 031328999 EMSL Analytical, Inc. 307 West 38th Street, New York, NY 10018 CustomerlD: AMBI99 Phone/Fax: (212) 290-0051 / (212) 290-0058 CustomerPO: htto://www.ern si .com [email protected] ProjectID;
*“'1: Ambient Group, Inc. Phone: (212)944-4615 Fax; (212) 944-4618 470 7th Avenue Received: 07/26/13 1:22 AM 12th Floor Analysis Date: 7/27/2013 New York, NY 10018 Collected: 7/26/2013
Project: 10493/101 BARCLAY STREET /A LEVEL
Test Report:Asbestos Analysis of Bulk Material Analyzed Non Asbestos Test Date Color Fibrous Non-Fibrous Asbestos Sample ID B-01-01 Description FIREPROOFING MURRY STREET AREA COLUMN 031328999-0001 Homogeneity Heterogeneous
PLM NYS 198.1 Friable 7/26/2013 Brown 25.00% Cellulose 22.00% Gypsum None Detected Unlabeled sample bag, number given by analyst 10.00% Glass 28.00% Non-fibrous (other) Vermiculite > 10% - Analysis via NYS ELAP 198.6 15.00% Vermiculite required. PLU NYS 198.6 NOB 7/27/2013 Beige 1.8% Glass This method does not remove vermiculite and may underestimate the level of asbestos present in a sample containing > 10% vermiculite. TEM NYS 198.4 NOB Not Analyzed
Sample ID B-01-02 Description FIREPROOFING ELECTRICAL ROOM HALLWAY 031328999-0002 Homogeneity Heterogeneous
PLM NYS 198.1 Friable 7/26/2013 12.00% Glass 25.00% Gypsum None Detected Unlabeled sample bag, number given by analyst 25.00% Cellulose 10.00% Non-fibrous (other) Vermiculite > 10% - Analysis via NYS ELAP 198.6 28.00% Vermiculite required. PLM NYS 198.6 NOB 7/27/2013 Beige 1.9% Glass This method does not remove vermiculite and may underestimate the level of asbestos present in a sample containing > 10% vermiculite. TEM NYS 198.4 NOB Not Analyzed
Sample ID B-01-03 Description FIREPROOFING ELECTRICAL ROOM 031328999-0003 Homogeneity Heterogeneous
PLM NYS 198.1 Friable 7/26/2013 Brown/Gray 3.00% Glass 15.00% Gypsum None Detected Unlabeled sample bag, number given by analyst 18.00% Cellulose 39.00% Non-fibrous (other) Vermiculite > 10% - Analysis via NYS ELAP 198.6 25.00% Vermiculite required. PLM NYS 198.6 NOB 7/27/2013 Beige 1.4% Glass This method does not remove vermiculite and may underestimate the level of asbestos present in a sample containing > 10% vermiculite. TEM NYS 198.4 NOB Not Analyzed
[initial Report From 07/27/2013 16:16:42~ ZZZZD Test Report 1982013-7.29.0 Printed; 7/27/2013 4:16:42 PM Page 1
NYC-WTC_000181895
OCR can misread numbers and units. Confirm readings against the page image before using them.
Related records
Browse subjects →Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
Same-box records
3 shared non-person entities · 1 shared topics · similarity 0.950
machine-extracted · confidence unavailable · Check page ↗3 shared non-person entities · 1 shared topics · similarity 0.946
machine-extracted · confidence unavailable · Check page ↗Filed elsewhere
NYC-WTC_000120128
Laboratory analysis results for bulk dust samples collected from 53 Park Place following the September 11 attacks.
3 shared non-person entities · 1 shared topics · similarity 0.954
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000092671
Laboratory report on TEM analysis of carpet mastic glue samples from residential building common corridors confirming absence of asbestos.
3 shared non-person entities · similarity 0.953
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000096232
Facsimile cover page transmitting asbestos and lead test results for a residential building at 17 Warren Street to the DEP.
3 shared non-person entities · 1 shared topics · similarity 0.949
machine-extracted · confidence unavailable · Check page ↗3 shared non-person entities · 1 shared topics · similarity 0.948
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000144595
Newspaper report detailing city health department guidance for owners of vehicles contaminated with asbestos dust from the World Trade Center site.
3 shared non-person entities · 1 shared topics · similarity 0.946
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000177279
Fax transmittal from EMSL Analytical to TRC Environmental Consultants regarding asbestos and lead analysis results for the 100 Church Street renovation.
3 shared non-person entities · 1 shared topics · similarity 0.946
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000177276
Document recording the receipt and project details for environmental samples submitted by TRC in March 2005.
3 shared non-person entities · 1 shared topics · similarity 0.945
machine-extracted · confidence unavailable · Check page ↗3 shared non-person entities · 1 shared topics · similarity 0.944
machine-extracted · confidence unavailable · Check page ↗3 shared non-person entities · 1 shared topics · similarity 0.943
machine-extracted · confidence unavailable · Check page ↗More like this page
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Similarity score 0.974 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000092671
Laboratory report on TEM analysis of carpet mastic glue samples from residential building common corridors confirming absence of asbestos.
Similarity score 0.973 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000092671
Laboratory report on TEM analysis of carpet mastic glue samples from residential building common corridors confirming absence of asbestos.
Similarity score 0.972 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000144595
Newspaper report detailing city health department guidance for owners of vehicles contaminated with asbestos dust from the World Trade Center site.
Similarity score 0.972 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000092671
Laboratory report on TEM analysis of carpet mastic glue samples from residential building common corridors confirming absence of asbestos.
Similarity score 0.972 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Similarity score 0.972 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Others also read
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000120128
Laboratory analysis results for bulk dust samples collected from 53 Park Place following the September 11 attacks.
Similar indexed content
NYC-WTC_000092671
Laboratory report on TEM analysis of carpet mastic glue samples from residential building common corridors confirming absence of asbestos.
Similar indexed content
Similar indexed content
Similar indexed content
NYC-WTC_000096232
Facsimile cover page transmitting asbestos and lead test results for a residential building at 17 Warren Street to the DEP.
Similar indexed content