NYC 9/11 Public Portal Document
TEM Asbestos (air) Count Sheet
Client Name: NYC BOE Volume (liters): 1944
Lab Group #: 7232 Filter Type / Filter Area: MCE 385 mm-
Lab Sample #: 4 Grid Opening Size: 0.01124
Client Sample #: 04 Area Examined: 0.04496 mm"
GRID BOX: Magnification: 20,000
GRID ID: Accelerating Voltage: 100 KeV
# Grid Openings: 4 Analysis Date: 3/27/02
Analysis Performed By:
ROMAN PEYSAKHOV
GO. Structure Structure Type Length ID of Structure N or EDS
(Nonadb
No F B C M >=05 M Chrys Amphibole Nonasb Ambig/ND
<5p Elements)
Ij
-J/(_
Struct = > 0.5p >5;I Aspect Ratio Grid acceptance:
y = Positive diffraction pattern properties conforming to <50% undissolved filter, overlapped or folded Totals
laboratory identification criteria observed <10% particulate coverage >50% coverage ate
least 20 unfolded or overlapped grid squares <5% Ip B C j M >5u
V= EDS spectrum conforming to laboratory holes or opaque areas
identification criteria observed Chrysotile \
AMPHIBOLES Amphibole
F = Single Fiber Amosite i
B = Bundle (<3 fibers <1 fiber diameter apart Crocidolite Ambiguous
C = Cluster (>3 Intersections) Anthophyllite Non-Asbestos )
T remolite ।
M = Matrix Non-Identified
Actinolite i
NSD = No Structures Detected
CONFIDENTIAL, CITY_21MC100_005803172
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000181664
OCR can misread numbers and units. Confirm readings against the page image before using them.