NYC 9/11 Public Portal Document
TEM Asbestos (air) Count Sheet
Client Name: NYC BOE Volume (liters): 1920
Lab Group #: 6684 Filter Type / Filter Area: MCE 385 mm-
Lab Sample #: 7 Grid Opening Size: 0 01124
Client Sample #: 07 Area Examined: 0.04496 mm-
GRID BOX: Magnification: 20,000
GRIDED: Accelerating Voltage: 100 KeV
# Grid Openings: 4 Analysis Date: 2/15/02
Analysis Performed By:
ROMAN PEYSAKHOV
GO, Structure ! Structure Type I Length ID of Structure N or V EDS
(Nonadb
No R B C Ml >=5|j Chrys Amphibole Nonasb Ambig/ND
No Coord Elements)
I <5|j
V
z iL -
A
, I
Struct = > 0.5u >5:1 Aspect Ratio 6nd acceptance;
V= Positive diffraction pattern properties conforming to <50% undissolved filter, ovedapped or folded Totals
laboratory identification criteria observed <10% particulate coverage >50% coverage ate
least 20 unfolded or overlapped grid squares <5% F B C
'/= EDS spectrum conforming to laboratory holes or opaque areas
identification criteria observed Chrysotile
AMPHIBOLES Amphibole
F = Single Fiber Amosite
B = Bundle (<3 fibers <1 fiber diameter apart Crocidolite Ambiguous
C = Cluster {>3 Intersections) Anthophyllite Non-Asbestos
Tremolite
M = Matrix
Actinolite I Non-Identified
NSD = No Structures Detected
I____________
CONFIDENTIAL, CITY_21MC100_003467942
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000181073