TEM Asbestos (air) Count Sheet
Client Name: NYC BOE Volume (liters): 1920
Lab Group #: 6645 Filter Type / Filter Area: MCE 385 mm-
Lab Sample #: 10 Grid Opening Size: 0.01124
Client Sample #: 10 Area Examined: 0.04496 mm-
GRID BOX: Magnification: 20,000
GRID ID: Accelerating Voltage: 100 KeV
# Grid Openings: 4 Analysis Date: 2/12/02
Analysis Performed By:
MARK PEYSAKHOV
GO. Structure Structure Type Length ID of Structure N or v EDS
(Nonadb
No Coord
No F B c M >=05 p Ctirys Amphibole Nonasb Ambig/ND
Elements)
<5p
CT
A' crvC
Struct = >0,5u >5:1 Aspect Ratio Grio acceptance:
V= Positive diffraction pattern properties conforming to <50% undissolved filter, overiapped or folded Totals
laboratory identification criteria observed <10% particulate coverage >50% coverage ate
least 20 unfolded or overlapped grid squares <5% F B C M >5|j
V= EDS spectrum conforming to laboratory holes or opaque areas
identification criteria obsen/ed Chrysotile
! AMPHIBOLES i Amphibole
F = Single Fiber , Amosite
B = Bundle (<3 fibers <1 fiber diameter apart Crocidolite Ambiguous
C = Cluster (>3 Intersections) i Anthophyllite Non-Asbestos
Tremolite
M = Matrix Actinolite Non-Identified
NSD = No Structures Detected
CONFIDENTIAL, CITY_21MC100_003467884
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000181033