NYC 9/11 Public Portal Document
TEM Asbestos (air) Count Sheet
Client Name: NYC BOE Volume /liters): 1936
Lab Group #: 6401 Filter Type / Filter Area: MCE 385 mm-
Lab Sample #: 6 Grid Opening Size: 0.01124
Client Sample #: 6 Area Examined: 0.04496 mm-
GRID BOX: Magnification: 20,000
GRID ID: Accelerating Voltage: 100 KeV
# Grid Openings: 4 Analysis Date: 1/22/02
Analysis Performed By:
MARK PEYSAKHOV
GO. Structure Structure Type Length ID of Structure N or v EDS i
No (Nonadb j
F B C M =05 p Chrys Amphibole : Nonasb Ambig/ND
No Coord <5u Elements)
J
Struct = > 0.5|j >5:1 .Aspect Ratio Grid acceptance:
V= Positive diffraction pattern properties conforming to undissolved filter, overlapped or folded Totals
laboratory identification criteria observed <10% particulafe coverage >50% coverage ate
EDS spectrum conforming to laboratory
least 20 unfolded or overlapped grid squares <5%
holes or opaque areas
F B C I M >5p
identification criteria observed Chrysotile
AMPHIBOLES Amphibole
F = Single Fiber Amosite
B = Bundle (<3 fibers <1 fiber diameter apart Crocidolite Ambiguous
C = Cluster (>3 Intersections) Anthophyllite Non-Asbestos
T remolite
M = Matrix Non-Identified
Actinolite
NSD = No Structures Detected J ......
CONFIDENTIAL, CITY_21MC100_003467443
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000180728