Mr. Bernard P. Orlan March 27, 2002 Indoor Air Quality Assessment Pages H.S. for Leadership & Public Service fM894) ATC Project No. 15-19125-0290 Real-Time Eymroxmental Measurements
ATC collected one hundred and forty (140) sets of real-time environmental measurements consisting of one hundred and twenty-eight (128) in the school building and twelve (12) outdoors. All fourteen floors of the school were surveyed. Field data sheets are found in the Attachment. Readings began at 10:11 A.M. and concluded after 6:23 P.M. The results are described below.
Temperature
Indoor dry' bulb temperature measurements ranged from 71.5 °F to 78.8 °F. One hundred and one (101) indoor measurements for temperature were above and twenty-seven (27) measurement were within the range of 68 to 75°F (at 50 percent relative humidity) recommended by ASHRAE Standard 55-1992 during the heating season (wintertime conditions). The outdoor temperature rar ge was 39.6 °F to 46.2 °F.
Relative Humidity’
The relative humidity indoors ranged from 26.2 percent to 39.9 percent. One hundred and twenty-one (121) of the indoor measurements for relative humidity were below and seven (7) measurements were within the ASHRAE-recommended range of 30 to 60 percent for occupant comfort. The outdoor relative humidity range was 22.4 to 34.0 percent.
Carbon Dioxide Concentration
Carbon dioxide concentrations indoors ranged from 487 ppm to 1398 ppm. One (1) of the indoor measurements for CO2 was above the ASHRAE Standard 62-1999 recommended maximum concentration of a700 ppm above the background level. The outdoor (background) CO2 concentration was 439 ppm. Therefore, the maximum acceptable level of CO2 at this location was 1139 ppm (background level + 700 ppm). The highest measurement was taken in the gymnasium at 12:54 PM with one (1) occupant. Levels above the recommended maximum do not indicate a health risk. Carbon dioxide measurements are used as an indicator of available outdoor air. The primary source of CO2 indoors is occupant respiration.
Carbon Monoxide Concentration
Carbon monoxide c:oncentrations indoors ranged from 1 ppm to 2 ppm. These concentrations were below the NPAAQS/ASHRAE guideline of 9 ppm. The outdoor CO concentrations ranged from 2 ppm- 6 ppm
Respirable Particulates (PM2,5)
Respirable particulate concentrations* indoors ranged between 3 pg/m^ to 20 pg/m^ with an average 6 pg/m-^- All of the indoor measurements for PM2.5 were below the NPAAQS of 65 pg/m3 24-houT average concentration of particulate matter 2.5 micrometers or less in aerodynamic diameter and the USEPA recommended concentration of 40 pg/m^ for sensitive individuals such as asthmatic people and children. The outdoor respirable particulate concentrations ranged from 20 pg/m^ to 68 pg/m^ with an average of 32 pg/m^. One (1) of the outdoor measurements for PM2.5 was above the NPAAQS of 65 pg/m^ 24-hour average
CONFIDENTIAL, CITY_21MC100_007741198 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000180185
OCR can misread numbers and units. Confirm readings against the page image before using them.
Related records
Browse subjects →Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
Same-box records
NYC-WTC_000179985
Letter from ATC Associates reporting indoor air quality measurements collected at a school on March 21, 2002.
13 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000175231
Memo reporting indoor air quality measurements collected at DeSoto School on August 26, 2002.
12 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000180188
Cover letter from ATC Associates to the NYC Board of Education submitting indoor air quality measurements for 90 Trinity Place in April 2002.
14 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000179972
Letter from ATC Associates reporting indoor air quality measurements collected at a school on March 8, 2002.
13 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗14 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗12 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000175150
Letter and report from ATC Associates regarding indoor air quality measurements collected at DeSoto School in August 2002.
12 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗12 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000177847
Cover letter and report detailing indoor air quality measurements collected at PS 234M on January 24, 2002, to evaluate building contamination.
12 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗11 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000177946
Letter reporting indoor air quality measurements conducted at P.S. 150M to evaluate conditions prior to re-occupancy.
11 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗Filed elsewhere
No available related records indexed in this group.
More like this page
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Similarity score 0.992 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000179972
Letter from ATC Associates reporting indoor air quality measurements collected at a school on March 8, 2002.
Similarity score 0.992 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Similarity score 0.986 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000179985
Letter from ATC Associates reporting indoor air quality measurements collected at a school on March 21, 2002.
Similarity score 0.984 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000180188
Cover letter from ATC Associates to the NYC Board of Education submitting indoor air quality measurements for 90 Trinity Place in April 2002.
Similarity score 0.984 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000175231
Memo reporting indoor air quality measurements collected at DeSoto School on August 26, 2002.
Similarity score 0.979 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Others also read
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
Similar indexed content
Letter from ATC Associates reporting indoor air quality measurements collected at a school on March 21, 2002.
Similar indexed content
NYC-WTC_000175231
Memo reporting indoor air quality measurements collected at DeSoto School on August 26, 2002.
Similar indexed content
Cover letter from ATC Associates to the NYC Board of Education submitting indoor air quality measurements for 90 Trinity Place in April 2002.
Similar indexed content
Letter from ATC Associates reporting indoor air quality measurements collected at a school on March 8, 2002.
Similar indexed content