Air sampling lab report for mercury vapor, Jan 2002

Machine-extracted title · confidence 95%

Laboratory report from ATC Associates detailing air sample results for mercury vapor collected at the School of Economics and Finance.

NYC-WTC_000179434–000179435
Page image
Scanned page image, NYC-WTC_000179434
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

104 East 25th Street New York. New York 10010 wwwatc-enviro com 212 353 8280 Fax 212 363 8306 ASSOCIATES INC

January 21, 2002

Mr. Bernard P. Orlan Director, Environmental Health and Safety New York City Board of Education 28-11 Queens Plaza North Long Island City, NY 11101

Re: Air Samples for Mercury Vapor High School for Economics and Finance (M833) 100 Trinity Place New York, New York ATC Project No. 15-19125-0291

Dear Mr. Orlan

ATC Associates, Inc. (ATC) is pleased to provide this letter report of air sampling for mercury vapor collected on January 14,2002, at the referenced school The New York City Board of Education (BOE) requested these samples to evaluate possible contammation in the school building.

ATC collected nine (9) samples for mercury vapor. Samples were collected for a minimum of ten (10) hours Seven (7) samples were collected inside the building and two (2) were collected outdoors One blank sample was also submitted. The samples were sent to PSC Analytical Services, Inc , an American Industrial Hygiene Association-accredited laboratory in Reading, PA A copy of the analytical report is provided in the attachment.

Samples for mercury vapor were collected using Carulite® (Hydrar) tubes connected to batteiy- powered sampling pumps calibrated to collect 0.2 liters of air per minute Analysis was performed by means of a mercury analyzer according to NIOSH Method 6009

The locations of the samples were. Roof by air intake; Outdoors by the Mam Entrance, Mam lobby; 3"^ floor by Stair B; 5**' floor Stair A; 7* floor hallway by the bridge; Kitchen 8* floor. Room 906, Room 1006.

The established regulatory value for mercury is intended for industrial workplace exposures and IS not generally applicable to office/school settings. There are no standards for mercury in indoor air in non-mdustnal situations.

SAMPLE RESULTS

The outdoor sample fi-om the Main Entrance (#Hgl) contained 0.0450 micrograms (ug) of Hg which equals an airborne concentration of 0.000375 milligrams per cubic meter (mg/m’) The blank contained 0.037 ug of Hg. The blank-corrected Hg concentration in Sample #Hgl is 0.00007 mg/m\

CONFIDENTIAL, CITY_21MC1OO_OO3459242

SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000179434

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000179434Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →