NYC 9/11 Public Portal Document
Scope of Work
ATC Associates, Inc. (ATC) was retained by New York City Board of Education (NYC-
BOE) to collect dust wipes to be analyzed for lead content. Dust wipe samples were
collected from areas recommended by the Parents Association consultant representative
Mr. Tom Fusillo of ENVIRON Corp, and approved by NYC- BOE and as specified in the
sampling protocol for the school. These areas are the following:
• C floor hallway ■>
• Cafeteria
• Gymnasium
• Auditorium
• Two classrooms facing South
• One classroom facing East
The purposed of the dust wipe sampling is to detennine if dust in the school contains
lead. ATC will be repeating this sampling preferably every Tuesday as per the
recommendation of ENVIRON Corp, and after the approval of NYC-BOE. This is the
second consecutive week dust samples were collected from P.S. 234M to be analyzed for
lead content after the sampling protocol is approved.
ATC’s representative Mr. Yiannis Efstatluou visited P.S. 234M located at 292 Greenwich
Street, New York, NY on January 29"', 2002. Dust wipes to be analyzed for lead content
were collected from the aforementioned areas indicated by ENVIRON and as specified
by the New York City Board of Education Environmental Health & Safety Unit and in
accordance with HUD protocols.
LEAD-IN-DUST SAMPLING
Lead-in-dust threshold levels
The New York City Health Code, part 173.14 and the Federal Departments of Housing and
Urban Development (HUD) and Environmental Protection Agency (EPA) have established
acceptable lead-in-dust levels for re-occupancy after a lead abatement has occurred
(commonly referred to as “final clearance” levels). As stated in the Code, final clearance
after abatement has taken place is achieved when dust wipe samples indicate lead levels
below those listed below:
For Windowsills: 250 ug/ft=
For Floors; 40 pg/ft^
Although the lead-in-dust samples collected at P,S. 234M were not collected in response to
lead abatement, tire same thresholds are used since no other regulations or standards are
applicable to dais project.
Sampling Methodology
P.S. 234M
(Satc
« s(oci«'e c INC
February 1, 2002
CONFIDENTIAL, CITY_21MC100_003390303
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000178639
OCR can misread numbers and units. Confirm readings against the page image before using them.