Indoor Air Quality Assessment Page 4
P. S. 150M ATC Project No. 15-19125-0289
* The measurements made during this assessment were instantaneous readings, the NPAAQS is
a 24-hour average.
TVOC Concentrations
TVOCs were not detected anywhere inside the building (0.0 ppm). The outdoor TVOC
concentration was also 0.0 ppm.
OBSERVATIONS
During this assessment, ATC noted the following:
• There was construction work going on in the plaza;
• The school building was occupied at the time of the assessment;
• No smoke odor was detected in the building;
FINDINGS
Based on the real-time measurements, the following findings are presented:
1. Concentrations of respirable particulates, CO and TVOCs were within applicable standards
and guidelines;
2. Twenty-three (23) temperature measurements were below the range of 73 to 79° F (at 50
percent relative humidity recommended by ASHRAE Standard 55-1992 during the heating
season (summertime conditions).
3. All measurements of relative humidity were within the ASHRAE recommended range of 30
to 60 percent for occupant comfort.
4. All of the CO2 measurements were below the ASHRAE Standard 62-1999 recommended
maximum concentration of <700 ppm above the background level
It is our pleasure to provide these indoor air quality services to the New York City Board of
Education. If you have any questions about this report, please call (212) 353-8280, extension
211 or 212.
Sincerely, Reviewed by:
ATC ASSOCIATES INC.
Yiannis Efstathiou James R. Cohn, CIH, CSP
Senior Project Manager Regional Manager
Industrial Hygiene Division
Attachment
CONFIDENTIAL, CITY_21MC100_005759679
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000177977
OCR can misread numbers and units. Confirm readings against the page image before using them.