NYC 9/11 Public Portal Document
Pace Analytical Services, Inc.
1700 Elm Street • Suite 200
Minneapolis, MN 55414
^ace Analytical Tsi: 612-607-1700
Fax: 612- 607-5^44
Method 8290 Blank Analysis Results
Client - ATC
Lab Sample ID BLANK-1516 Matrix WIPE
Filename F20320A_05 Dilution NA
Total Amount Extracted 1 m2 Extracted 03/14/2002
ICAL Date 01/24/2002 Analyzed 03/20/2002 11;49
CCal Filename(s) F20320A_01 & F20320A_16 Injected By MASS
Native Cone EMPC LRL Internal ng's Percent
Isomers ng/m2 ng/m2 ng/m2 Standards Added Recovery
2,3,7,8-TCDF ND 0.00200 2,3,7,8-TCDF-13C 2.00 69
Total TCDF ND 0.00200 2,3,7,8-TCDD-13C 2.00 63
1,2,3,7,8-PeCDF-13C 2.00 71
2,3,7,8-TCDD ND 0.00200 2,3,4,7,8-PeCDF-13C 2.00 69
Total TCDD ND 0.00200 1,2,3,7,8-PeCDD-13C 2.00 67
1,2,3,4,7,8-HxCDF-13C 2.00 109
1,2,3,7,8-PeCDF ND 0.01000 1,2,3,6,7,8-HxCDF-13C 2.00 73
2,3.4,7,8-PeCDF ND 0.01000 2,3,4,6,7,8-HxCDF-13C 2.00 81
Total PeCDF ND 0.01000 1,2,3,7,8,9-HxCDF-13C 2.00 88
1,2,3,4,7,8-HxCDD-13C 2.00 100
1,2.3,7,8-PeCDD ND 0.01000 1,2,3,6,7,8-HxCDD-13C 2.00 72
Total PeCDD ND 0.01000 1,2,3,4,6.7.8-HpCDF-13C 2.00 75
1,2,3,4,7,8,9-HpCDF-13C 2.00 69
1,2,3,4,7,8-HxCDF ND 0.01000 1,2,3,4,6,7,8-HpCDD-13C 2.00 77
1,2,3,6,7,8-HxCDF ND 0.01000 OCDD-13C 4.00 68
2,3,4.6,7,8-HxCDF ND 0.01000
1,2,3.7,8,9-HxCDF ND 0.01000 1,2,3,4-TCDD-13C 2.00 NA
Total HxCDF ND 0.01000 1,2.3,7,8,9-HxCDD-13C 2.00 NA
1,2,3,4,7,8-HxCDD ND 0.01000 2,3,7.8-TCDD-37CI4 0.20 66
1.2,3,6,7,8-HxCDD ND 0.01000
1,2,3,7,8,9-HxCDD ND 0.01000
Total HxCDD ND 0.01000
1,2,3,4,6,7,8-HpCDF ND 0.01000 Total 2,3,7.8-TCDD
1,2,3,4,7,8.9-HpCDF ND 0.01000 Equivalence; 0.0011 ng/m2
Total HpCDF ND 0.01000 (Using ITE Factors)
1,2,3,4,6,7,8-HpCDD 0.023 0.01000 J
Total HpCDD 0.046 0.01000 J
OCDF ND 0.02000
OCDD 0.850 0.02000
Cone = Concentration (Totals include 2,3,7,8-substituted isomers). I = Interference
EMPC = Estimated Maximum Possible Concentration E = PCDE Interference
LRL = Lower Reporting Limit ND = Not Detected
J = Concentration detected is below the calibration range NA = Not Applicable
P = Recovery outside of target range NC = Not Calculated
A = Detection Limit based on signal-to-noise measurement • = See Discussion
Report No.... 02-1054706
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc.
CONFIDENTIAL, CITY_21MC100_003444425
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000177789
OCR can misread numbers and units. Confirm readings against the page image before using them.