QWTC PROJECT MONITOR LOG 4. Project #: 5. Work Area(s): Parti 1. Client; 2. Ptpject Name: . V FC 1___ 3. ProjectAdd^^ 4a. Task #: 22. 6. Contractor: 7. Contractor's Foreman: 8. ATC^epf^sentative: 9. Date:

Type of Project: Full-Containment Tent-Containment Glovebagging Other

Size of Proiect: Large (> 160 sq. ft., 260 lin. ft. of ACM) Small (< 160 sq. ft., 260 lin. ft.)

Phase of Abatement: Pre-abatement Sampling Prep Removal j;22rCleaning

Encapsulation Waste Load-out Finals

FULL-CONTAINMENT ABATEMENT

Work Area Location (floor, room, section):

Preparation of Work Area: Yes (Indicate prep work pei/ormed in 1 -10) N/A (If already completed)

1. Construction of Decon: Yes No 2. Ceiling Poly: Yes No 3. Critical Barriers (CBs): Yes No 4. Wall Poly: Yes No 5. Removal to establish CBs: Yes No 6. Floor Poly: Yes No 7. Negative air: Yes No 8. Pre-cleaning; ) Yes No 9. Prep work completed: Ye: No 10. Temporary Power: / Yes No 11. Other_______________ Yefe No 12. Prep-Inspection Passes: Yes No (Explain why)

Removal: Yas (Complete 1 - 5) N/A

1. Type of ACM: Pipe Insulatic^ Duct Insulation Fireproofing Ceiling Tile Boiler Insulafon Transite Boards FlooiTile Other:

2. Negative air pressure > 0.02 in. of wa er: Yes No 3. Amended water u^ed during removal: Yes No 4. Critical barriers intact for shift's duratit n: Yes No 5. Proper Decon procedures followed: Yes No

Cleaning: Yes (Complete 1 - 6) N/A

1.1 st Stage 2nd Stage\ 3ra 3rd Stage 2. 12/12-hour waiting period after 1st cleaning: 3. Removal of 1 st poly layer after 1 st clearing: Yes No 4. 4/12-hour wailing period after 2nd cleaning: Yes No 5. Removal of 2nd poly layer after 2nd cleahtojig: Yes No 6. 1/12-hour waiting period after 3rd cleaning: Yes No

TENT-CONTAINMENT ABATEMENT

Work Area Location (floor, room, section):

Preparation of Work Area: Yes (Indicate prep work performed in 1 - 6) N/A (If already completed)

1. Construction of Tent: Yes Io 2. Pre-cleaning: Yes No 3. Construction of Decon: Yes Io 4. Negative Air: Yes No N/A 5. Prep work completed: Yes Io 6. Pref-inspectiAn passes: Yes No

Removal: 1. Type of ACM: Pipe Insulaion Duct Insulatic n Fireproofing Ceiling Tile Boiler InsBlation Transite Boat Is Floor Tile Other: 2. Method or Removal: removal within tent ------ Gross , Glovebag removal within tent (check 3 through 8) (If Glovebag Removal Check 3 through 8) / 3. Glovebags smoke-tested: I Yes No 4. Glovebags attached to smooth surface: F Yes No 5. Amended water used: Yes No 6. Removal included cleaning and encapsulation: Yes No 7. Open/damaged ends of insul. sealed: Yes No 8. Glovebags vacuumed, double-bagged: Yes No

Continued on Back Form NY-8 1/01

CONFIDENTIAL, CITY_21MC100_003446222 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000177450

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000177450Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →