NYC 9/11 Public Portal Document
TEM Asbestos (air) Count Sheet
Client Name: NYC BOE Volume (liters): 1840
Lab Group #: 7444 Filter Type / Filter Area: MCE 385 mm-
Lab Sample #: 11 Grid Opening Size: 0.01124
Client Sample #: 11 Area Examined: 0.04496 mm*
GRID BOX: Magnification: 20,000
GRID ID: Accelerating Voltage: 100 KeV
# Grid Openings: 4 Analysis Date: 4/17/02
Analysis Performed By: ^/f
ROMAN PEYSAKHOV
GO. Structure Structure Type Length ID of Structure N or v
(Nonadb j
No F B C M >-05 p Chrys Amphibole Nonasb Ambig/ND
No Coord <5p Elements)
if
-U—
-Jc—
Struct = > 0.5p >5:1 Aspect Ratio Grid acceptance;
V- Positive diffraction pattern properties conforming to <50% undissolved filter, overlapped or folded Totals
laboratory identification criteria observed <10% particulate coverage >50% coverage ate
least 20 unfolded or overlapped crd squares <5% f 1 B I C j M , >5p
v= EDS spectrum conforming to laooratory holes or opaque areas L
Identification criteria observed Chrysotile
AMPHIBOLES Amphibole
F = Single Fiber Amosite
3 = Bundle {<3 fibers <1 fiber diameter apart Crocidolite
Ambiguous j
C = Cluster (>3 Intersections; Anthophyllite i Non-Asbestos (
Tremolite
M = Manx
Actinolite i Non-Identified ]
NSD - No Structures Detected
CONFIDENTIAL, CITY_21MC100_003471114
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000176955