NYC Law Department release
Independent mirror · updated as the City releases more · v1.3.2
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

Asbestos TEM analysis results, 345 Chambers Street, Oct 2001

Machine-extracted title · confidence 95%

ATC Environmental report on asbestos fiber analysis by TEM for samples collected at a school at 345 Chambers Street.

NYC-WTC_000176452
Page image
Scanned page image, NYC-WTC_000176452
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/23/01

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Di.spersive X-RAY Spectroscopy (EDS) Method: ?>HER.A Final Rule, SPA Federal Register (40 CFR, Part 763i, Vol. 52, No. 210, October 30, 1987

Sample Identification Analysis Parameters

Project/Site; New Stuyx^esant H.S., 345 Chambers St., NY', NY TEM Sample No.: 5739 61955 Exterior Interior of Building & Roof Date Received: 10722/01 Grid Openings Analyzed:__ 4

Project Sample No.: 2D Average Grid Opening: 106.00 um

Air Volume: 1944 liters Total Area Analyzed: 0.04 50 mTn2

Filter Type: MCE 25 mm dram,, Pore Size: 0.45 um Analytical Sensitivity : 22.2 s/mrr.2 Effective Area: 385mm2 0.0044 s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fiber;:: Bundles Clusters Struct. Struct > = 5um Struct/mrri2 Struct/cc nqm/m3

Chrysotila Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Amphibole A.sbestos 0 0 0 0 0 0 0.0 0 . 0000 0

Ambiguous Cl 0 0 0 D 0 0.0 0.0000 0

Total asb'sstos {includes ambiguous structures) 0 0 0.0 0.0000 0 Non-Asbestos 0 0 0 0 0 0 0. 0 0.0000 N/A No Identification 0 0 0 0 0 0 0.0 0.0000 N/A

Totals {All Structures: 0 0 0. 0 0.0000 N/A The estimated uncertainty C'f this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type; None detected

The j\nalysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by.-

Roman Peysakhcv Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CONFIDENTIAL, CITY_21MC100_003470321 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000176452

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000176452Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →