ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/22/01

ASBESTOS FIBER hJTALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification (oy Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS. Method; AIERA Final Rule, EPA Federal Register (40 CFR, Part 763;. Vol. 52, No. 210, October 30, 1987

Sample Identification Analysis Parameters

Project/Site: New Spuvvesan: H.S., 345 Chambers St., NY,. NY TEM Sample No.: 5737 61836 Exterior & Interior of Building & Roof Date Received:10/21/0i Grid Openings Analyzec:__4

Project Scjmple No. : 15 Average Grid Opening; 106.00 um

Air Volume :1920 3J^^rs Total Area Analyzed: C.0450 mm2

F11e 1' T\qie : MCE 25 mm diann , Pore Size: 0.45 urn Analytica1 Sensitivity: 22.2 s/mm2 Effective Ares: 385mm2 0.0045 s/cc

FIBROLfS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct > = 5urr. Struct/n»m2 Struct/cc ngni/m3

Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Amphibole Asbe.stos 0 0 0 0 0 0 0.0 0.0000 0

Ambiguous ij 0 0 0 0 0 0.0 0.0000 0

Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0 Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A No Identification (J 0 0 0 0 0 0. 0 0.0000 N’/A

Totals (All Structures) 0 0 0.0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED); None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by; Report Reviewed by;

Yarek Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CONFIDENTIAL, CITY_21MC100_003470270 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000176443

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000176443Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →