NYC 9/11 Public Portal Document
ATC Environmental, Inc.
104 East 25th Street
New York, New York 10010
N.Y.C. Board of Education Approved N.Y. State ELAP #10879
28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187
Long Island City, NY 11101 Report Date: 10/20/01
ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TBM)
With Fiber Identification by Selected-Area Electron Diffraction iSAEDi and Energy-Dispersive X-RAY Spectroscopy (EDS)
Method: T^HERA Final Rule, IP.F Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987
Sample Identificacion Analysis Parameters
Projecc/Site: New Stuyvesant H.S., 345 Chambers St., NY, NY TEM Sample No.; 5730 61706
Various Siter Inside and Outside the Building
Date Received; 10/19/01 Grid Openings Analyzed:__4
Project Sample No.: 16 Average Grid Opening: 106.00 um
Air Volume: 1928 liters Total Area Analyzed; C.0450 mm2
Filter Tvi>e: MC2 25 mm dian.. Pore Size: 0.45 um Analytical Sensitivity :22^2 s2rnm2
Effective Area; 385 mm2 0.0044 s/cc
FIBROUS PARTICULATES ANALYZED
Number Observed CONCENTRATION
Total
Single Matrix Total. struct. Filter Air
Fibers Bundles Clusters Struct. Struct > = 5um Struct/mm2 Struct/cc nqm/m3
Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Amphibole Asbestc.s 0 0 0 0 0 0 0.0 0.0000 0
Ambiguous c 0 0 0 0 0 0.0 0.0000 0
Total tasbesLos (includes ambiguous structures) 0 0 0.0 0.0000 0
Non-Asbestcs C 0 0 0 0 0 0. 0 0.0000 K/A
No Identification 0 0 0 0 0 0 0.0 0.0000 N/A
Totals (All Structures) 0 0 0. 0 0.0000 N/A
The estimated uncertainty cf this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED): None detected
Amphibole Asbestos Type: None detected
The Analysi.3 was carried out in accordance with the approved TEM method.
This laboratory is in compliance with the quality specified for the method.
Analyzed by: Report Reviewed by:
Roman Peysakhov Michael A. Gorycki, Ph.D.
Director of Electron Microscopy
CONFIDENTIAL, CITY_21MC100_003470176
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000176433
OCR can misread numbers and units. Confirm readings against the page image before using them.