Asbestos fiber analysis by TEM, New York City schools, Oct

Machine-extracted title · confidence 50%

ATC Environmental lab report detailing asbestos fiber identification via TEM and EDS methods at a school site in October 2001.

NYC-WTC_000176424
Page image
Scanned page image, NYC-WTC_000176424
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010 N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/18/01

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification oy Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method; AHER7k Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987

Sample Identification Analysis Parameters

Froject/Site; Nev; Stuyvesant H.S., 345 Chambers St., NY, NY TEM Sample No.: 5725 61645 Exterior S. Interior of Building &. Roof Date Received: 10/18/01 Grid Openings Analyzed:__ 4

Project Sample No . : i .3 Average Grid Opening; 106.00 urn

Air Volume:19361iter? Total Area Analyzed: 0.0450 mm2

Filter Tvoe: MCE 25 mm diam. Pore Size: 0.45 urn Analytical Sensitivity; 22.2 s/mm2 Effective Ares; IP5 mTn2 0.0044 s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single- Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct >=5um Struct/mm2 Struct/cc nqm/m3

Chrysotile /isbestos 0 0 0 0 0 c 0,0 0,0000 0

Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Ambiguous 0 0 0 0 0 0 0.0 0 . 0000 c

Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 Non Asbest.os 0 0 0 0 0 0 C.0 0.0000 N/A No Identification 0 0 0 0 0 0 C.0 0 . 0000 N/A

Totals {All Structures) 0 0 C.0 0.0000 N/A The estimeited uncertainty cf this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by; Report Reviewed by:

Michael A. Gorycki, Ph.D. Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CONFIDENTIAL, CITY_21MC100_003470129

SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000176424

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000176424Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →