NYC 9/11 Public Portal Document
ATC Environmental, Inc.
104 East 25th Street
New York, New York 10010
N.Y.C. Board of Education Approved N.Y. State ELAP #10879
28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187
Long Island City, NY 11101 Report Date: 10/16/01
ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM)
With Fiber Identification oy Selected-Area Electron Diffraction (SAEDi and Energy-Dispersive X-RAY Spectroscopy (EDS)
Method: AHER;\ Final Rule, i^PA Federal Register (40 CFR, Part 763), Vol. 52, No. 21C, October 30. 1967
Analysis Parameters
Project/Site: Nevi Stuyvesant H.S., 345 Chambers St., NY, NY TEM Sample No.: 5698 61345
Exterior Interior of Buildinq & Roof
Date Received:1££15/^ Grid Openings Analyzed;__4
Project Sample No.: NSHS-E:r-1C715-12 Average Grid Opening: 106.00 um
Air Volume .-i^lTlicers. Total Area Analyzed :^0;045 0 jTim2.
Filter Ty^e: MCE 25 mm diam.. Fore Size: 0.45 um Analytical Sensitivity: 22.2 s/mm2
Effective Aiea: 385 mm2 0.0045 s/cc
FIBROUS PARTICULATES ANALYZED
Number Observed CONCENTRATION
Total
Single' Matrix Total. Struct. Filter Air
Fibers Bundles Clusters Struct. Struct >=5uni Struct/mm2 Struct/cc nqm/mG
Chrysotile; Asbestos 0 G 0 0 0 c 0.0 0.0000
Amphibole Asbestos 0 0 0 0 0 0 C.0 0.0000
Ambiguous 0 0 0 0 0 0 0,0 0.0000 0
Total astxsstos (includes ambiguous structures) 0 0 0.0 0.0000 c
Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A
No Identification 0 0 0 0 0 0 o.c 0.0000 N/A
Totals (All Structures) 0 0 0.0 0.0000 N/A
The estimcited uncertainty cf this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED): None detected
Amphibole Asbestos Type: None detected
The Analysis was carried out in accordance with the approved TEM method.
This laboratory is in compliance with the quality specified for the method.
Ariel lyzed by: Report Reviewed by:
Marek Peysakhov Michael A. Gorycki, Ph.D.
Director of Electron Microscopy
CONFIDENTIAL, CITY_21MC100_003470043
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000176420
OCR can misread numbers and units. Confirm readings against the page image before using them.