NYC Law Department release
Independent mirror · updated as the City releases more · v1.3.2
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

Asbestos fiber TEM analysis report, Oct 13 2001

Machine-extracted title · confidence 95%

Air sampling results from the exterior and interior of a high school analyzing asbestos fibers using transmission electron microscopy.

NYC-WTC_000176416
Page image
Scanned page image, NYC-WTC_000176416
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010 N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date; 10/14/01

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification Dy Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS Method: A)iERA Final Rule, f:pa Federal Register [40 CFR, Part 7631, Vol. No. 210, October 50, 1987

Sample Ideatification Analysis Parameters

Project/Si le; New Stuyvesant IRS., 34 5 Chambers St.,. NY, NY TEM Sample No.; 5687 61063 Exterior & ii.terior of Building & Roof Date Rece.ived: 10/14/01 Grid Openings Analyzed:__4

Project Sample No.: USKS-EIR-10/13-10 • Average Grid Opening: 105.00 um

Air Volume: 1908 liters Total Area Analyzed;0,0jo0 mr^

F.Liter Typie; MCE 25 trun diar. Pore Size: 0.45 um Analytical Sensitivity .22;2 s£mm2 Effective A.rea : 385 mm2 0 . 0045 s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct > = 5um Struct/mm2 Struct/cc nqm/m3

Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Amphibole Asbestos 0 0 0 C 0 0 0.0 0.0000 0

A’Ttbiguous 0 0 0 0 0 0 0. 0 0.0000

Total asbestos (includes ambiguous structures) 0 0 0. 0 0.0000 0 Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A No Identification 0 0 0 0 0 0 0. 0 0.0000 N/A

Tctals (All Structures) 0 0 0,0 0 . 0000 N/A Trie estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED); None detected Amphibole Asbestofs Type: None detected

Th€5 Analysis was carried out in accordance with the approved TEM method. This laboratcry is in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by;

Roman Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CONFIDENTIAL, CITY_21MC1OO_OO3469986 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000176416

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000176416Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →