NYC 9/11 Public Portal Document
104 East 25th St, Wth Floor
4.
New York, New York 10010
WWW atc-enviro com
212 353 8280
Fax 212 353 8306
ASSOCIATES INC.
November 25, 2002
Mr Bernard P Orlan
Director, Environmental Health & Safety
New York City Department of Education
28-11 Queens Plaza North
Long Island City, NY 11101-4008
Re: Wipe Samples for Dioxins
P. S. 124 Manhattan
ATC Project No. 15-19125-0350
Dear Mr Orlan
ATC Associates Inc (ATC) is pleased to provide this report of the results of the wipe-samples
for polychlorinated dibenzo-p-dioxins (PCDDs)and dibenzofurans (PCDFs) collected on
September 12, 2002, at the referenced location The New York City Department of Education
(DOE) requested these samples to evaluate possible contamination in the school building
Scope of Work
The samples were collected using gauze pads and hexane as a solvent The solvent was provided
and samples were analyzed by Pace Analytical Services, Inc (Pace) of Minneapolis, MN, a
laboratory experienced in dioxin analysis The analysis was performed by modified EPA
Method 8290 using combined capillary column gas chromatography/high resolution mass
spectrometry
Tenzin Namgyal, Industrial Hygienist of ATC’s New York City office, collected the samples
consistent with generally accepted industrial hygiene practices There were inherent limitations
created by constraints of time, operational and work practice variability, variations in
contaminant concentrations, and sampling and analytical accuracy The results of the sampling
represent conditions found on the date the samples were collected
Results
ATC submitted three wipe samples for PCDDs/PCDFs (plus one blank) to Pace for analysis
Samples were taken from representative floor areas throughout the building The sample area for
each sample was one square meter (1 m^) The areas sampled were
• Lobby-Mam Entrance
• 2nd Floor Hallway by Room 222,
• srd Floor Hallway by Room 307
CONFIDENTIAL, CITY_21MC100_003431534
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000175545