Air sampling for hydrocarbons, P.S. 124, Sept 2002

Machine-extracted title · confidence 98%

Report from ATC Associates detailing volatile hydrocarbon air sampling results conducted at a New York City Department of Education school.

NYC-WTC_000175518–000175519
Page image
Scanned page image, NYC-WTC_000175518
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

104 East 25th St, 10th Fl New York, New York 10010 wwwatc-enviro com 212 353 8280 Fax 212 353 8306 ASSOCIATES INC

September 9, 2002

Mr. Bernard P. Orlan Director, Environmental Health and Safety New York City Department of Education 28-11 Queens Plaza North Long Island City, NY 11101

Re: Air Sampling for Hydrocarbons P. S. IM ATC Project No. 15-19125-0340

Dear Mr Orlan:

ATC Associates, Inc. (ATC) is pleased to provide this report of the results of air sampling for I volatile hydrocarbon compounds conducted on August 27, 2002, at the referenced school The New York City Department of Education (DOE) requested this sampling prior to the resumption of classes to verify that acceptable indoor air quality is being maintained

Scope of Work

ATC collected three (3) samples for hydrocarbon compounds (HC) at specified locations. Samples were collected for ten (10) hours using activated coconut shell charcoal tubes coimected to battery-powered sampling pumps at a flow rate of 0.2 liters per minute. Pumps were calibrated before and after each sampling period One blank tube was also submitted. The samples were sent to PSC Analytical Services, Inc., an Amencan Industnal Hygiene Association-accredited laboratory in Reading, PA Analysis was performed by capillary gas chromatography/flame ionization detection (OSHA Method 7)

Wagdi Abdelshahid, Industnal Hygienist and Jimmy Choy, Environmental Technician from ATC’s New York City office, conducted the sampling consistent with accepted industnal hygiene practices The results represent conditions on the day the samples were collected.

Each sample was analyzed for a panel of sixteen (16) specific HC compounds. These compounds were, pentane, acetone, methylene chlonde, hexane, chloroform, methyl chloroform, benzene, 1,2-dichloroethane, tnchloroethylene, toluene, perchloroetyhylene (tetrachloroethylene), chlorobenzene, ethylbenzene, styrene, cumene and xylenes. In addition, two non-identified peaks, total other A-hydrocarbons and total other B-hydrocarbons, were reported. The A- hydrocarbons are those, such as gasoline or light alcohols, with boiling points less than that of benzene (176"F). The B-hydrocarbons are those, such as mineral spints or petroleum naphtha, with boiling points greater than that of benzene. A copy of the analytical laboratory report is attached.

CONFIDENTIAL, CITY_21MC100_003431331 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000175518

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000175518Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →