NYC 9/11 Public Portal Document
104 East 25th St., 10th Fl
New York. New York 10010
www.atc-enviro.com
212.353.8280
Fax 212.353.8306
ASSOCIATES INC
September 16, 2002
Mr. Bernard P. Orlan
Director, Environmental Health & Safety
New York City Department of Education
28-11 Queens Plaza North
Long Island City, NY 11101-4008
Re: Air Sampling for Silica
DeSoto/PS 130 M
ATC Project No. 15-19125-0345
Dear Mr. Orlan:
ATC Associates Inc. (ATC) is pleased to provide this report of the results of air
monitoring for silica-containing dust conducted on August 26, 2002, at the referenced
school. The New York City Department of Education (DOE) requested this monitoring
prior to the resumption of classes to verify that acceptable indoor air quality is being
maintained.
Scope of Work
ATC collected a total of three (3) samples (and one blank) for respirable dust using pre
weighed 37mm PVC filters connected to size-selective cyclones to remove the larger
(non-respirable) particles prior to deposition on the filters. All of the samples were
collected indoors. The samples were sent to PSC Analytical Services, Inc., an American
Industrial Hygiene Association accredited laboratory in Reading, PA. Analysis for silica
was performed by x-ray diffraction according to OSHA Method 142. A copy of the
analytical report is attached.
Mr. Wagdi Abdelshahid, and Mr. Tenzin Namgyal, Industrial Hygienists of ATC’s New
York City office, collected the samples consistent with generally accepted industrial
hygiene practices. As with all such sampling, there were inherent limitations created by
constraints of time, operational and work practice variability, variations in air
contaminant concentrations and sampling and analytical accuracy. The results of the
sampling represent conditions found on the dates the samples were collected.
Results
Samples were obtained in the following locations: 1st floor Main Lobby, 4th floor
hallway by Stair C, and Sth floor hallway by Stair B.
The results of all of the samples were below the detection limit for silica (<5 micrograms
per sample).