NYC 9/11 Public Portal Document
Pace Analytical Services, Inc.
1700 Elm Street - Suite 200
Minneapolis, MN 55414
^ace Analytical Tel; 612-607-1700
Fax- 612- 607-6444
Method 8290 Blank Analysis Results
Client - ATC ASSOCIATES
Lab Sample ID BLANK-2193 Matrix WIPE
Filename F20928A„05 Dilution NA
Total Amount Extracted 1.00 m2 Extracted 09/21/2002
ICAL Date 09/26/2002 Analyzed 09/28/2002 16:24
CCal Filename(s) F2O927B_16 & F20928A_16 Injected By JAS
Native Cone EMPC LRL Internal ng's Percent
Isomers ng/m2 ng/m2 ng/m2 Standards Added Recovery
2,3,7,8-TCDF ND 0.0023 A 2,3,7,8-TCDF-13C 2.00 71
Total TCDF ND 0.0020 2,3,7,8-TCDD-13C 2.00 69
1,2,3,7,8-PeCDF-13C 2.00 77
2,3,7,8-TCDD ND 0.0028 A 2,3,4,7,8-PeCDF-13C 2.00 74
Total TCDD ND 0.0020 1,2,3.7,8-PeCDD-13C 2.00 77
1,2,3,4,7,8-HxCDF-13C 2.00 gg
1,2.3,7,8-PeCDF ND 0.0100 1,2,3,6,7,8-HxCDF-13C 2,00 73
2,3,4,7,8-PeCDF ND 0.0100 2,3,4,6,7,8-HxCDF-13C 2,00 85
Total PeCDF ND 0.0100 1,2,3,7,8,9-HxCDF-13C 2,00 72
1.2.3.4,7,8-HxCDD-13C 2.00 gs
1,2,3,7,8-PeCDD ND 0.0100 1,2,3,6,7,8-HXCDD-13C 2.00 74
Total PeCDD ND 0.0100 1,2,3,4,6,7.8-HpCDF-13C 2.00 77
1,2,3.4,7,8,9-HpCDF-13C 2.00 66
1,2,3,4.7.8-HxCDF ND 0.0100 1.2.3,4,6,7,8-HpCDD-13C 2.00 70
1,2,3,6,7,8-HxCDF ND 0.0100 OCDD-13C 4.00 81 *
2,3,4,6.7,8-HxCDF ND 0.0100
1,2,3,7,8,9-HxCDF ND 0.0100 1,2,3,4-TCDD-13C 2.00 NA
Total HxCDF ND 0.0100 1,2,3,7.8,9-HxCDD-13C 2.00 NA
1,2.3,4,7.8-HxCDD ND 0.0100 2,3,7,8-TCDD-37CI4 0.20 68
1,2,3,6.7.8-HxCDD ND 0.0100
1,2,3,7.8.9-HxCDD ND 0.0100
Total HxCDD ND 0.0100
1,2,3,4.6.7.8-HpCDF ND 0.0100 Total 2.3,7.8-TCDD
1,2,3,4,7,8,9-HpCDF ND 0.0100 Equivalence: 0.000034 ng/m2
Total HpCDF ND 0.0100 (Using ITE Factors)
1,2,3,4,6,7,8-HpCDD ND 0.0100
Total HpCDD ND 0.0100
OCDF ND 0.0200
OCDD 0.034 0.0200 J
Cone = Concentration (Totals include 2,3,7,8-substituted isomers). I = Interference
EMPC = Estimated Maximum Possible Concentration E = PCDE Interference
LRL = Lower Reporting Limit ND = Not Detected
J = Concentration detected is below the calibration range NA = Net Applicable
P = Recovery outside of target range NC = Not Calculated
A = Detection Limit based on signal-to-noise measurement * = See Discussion
Report No.... 1061865
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc,
CONFIDENTIAL, CITY_21MC100_003430432
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000175157
OCR can misread numbers and units. Confirm readings against the page image before using them.