40 Rector Holdings, LLC ATC Project No.: 19855-0001 C/0 Tannenbaum Helpern Syracuse & Hirschtritt LLP October 25, 2001 Ambient Air Sampling - 40 Rector Street Page 1 Of 7
n General ATC Associates Inc. (ATC), was retained by 40 Rector Holdings LLC to provide ambient air sampling on floors 1 through 19 in concert with a two phase building-wide cleaning program and to perform a general indoor air quality (lAQ) assessment of the building following the collapse of the World Trade Center Buildings. The purpose of the ambient m air sampling was to ascertain the presence or absence of airborne asbestos, whereas, the lAQ assessment was to determine ambient temperature, relative humidity, carbon dioxide (CO2), carbon monoxide (CO), respirable particulates and total volatile organic compounds (TVOC) as compared to commonly accepted guidelines within the occupied LJ spaces of 40 Rector Street. Ambient air sampling services were provided on September 27 - 28, 2001 upon completion of the initial cleaning of the entire building, and between October 22 -23, 2001 upon completion of the subsequent cleaning of the entire building. lAQ services were provided on October 1,2001. Per ATC proposals 15-2001-0909121, 121a, & 121b, the work performed involved the collection of ambient air samples from representative locations on each occupied floor n and the collection of representative lAQ measurements. All ambient air samples were collected and analyzed in accordance with the AHERA Transmission Electron Microscopy (TEM) method as set forth at 40 CFR Part 763, Subpart E, Appendix A. ATC has selected as a criteria for acceptable ambient air sample sets, the AHERA re-occupancy requirement following an asbestos abatement action of an average of less than 70 asbestos structures per square millimeter (<70 s/mm^) per sample set. All sample sets collected met the AHERA requirement at the time of testing; this criteria is appropriate even thought the cleaning events were not conducted as asbestos abatement projects because the AHERA requirement is a stringent reoccupancy requirement which is designed to be protective of n children (which is a more sensitive occupancy than the expected users of the building). All lAQ parameters measured during the lAQ assessment were within recommended guideline ranges. However, at the time of sampling, an odor of smoke was detected in n several locations within the subject building. This odor infiltrated the building from fires at the nearby World Trade Center site. This odor does not constitute a health hazard although building occupants may consider the sawr unpleasant and annoying. Sensitive individuals, such as asthmatics, may find the odor irritating. As a potential remedy to the odor, ATC provided a recommendation on October 2, 2001 for steps to minimize the odor entrainment into the building. The recommendation suggested that the building consider installing charcoal-impregnated filters on the HVAC system intakes to reduce odor entrainment: restrict to the extent possible access to the lobby via the revolving door only '.. 1 which would minimize odor infiltration and limit odor movement via the elevator shafts; and to perform daily wet-wiping and moping of the lobby with a standard cleaner or detergent solution. As of October 23, 2001, all three recommendations have successfully been implemented with satisfactory results in reducing odor entrainment into the building.
ATC Associates Inc. © 2001
NYC-WTC_000174833
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
No available related records indexed in this group.
NYC-WTC_000177887
Letter and report detailing real-time indoor air quality monitoring conducted at the school in December.
4 shared non-person entities · 1 shared topics · similarity 0.939
machine-extracted · confidence unavailable · Check page ↗5 shared non-person entities · 1 shared topics · similarity 0.938
machine-extracted · confidence unavailable · Check page ↗5 shared non-person entities · 1 shared topics · similarity 0.938
machine-extracted · confidence unavailable · Check page ↗3 shared non-person entities · similarity 0.938
machine-extracted · confidence unavailable · Check page ↗4 shared non-person entities · 1 shared topics · similarity 0.938
machine-extracted · confidence unavailable · Check page ↗5 shared non-person entities · 1 shared topics · similarity 0.937
machine-extracted · confidence unavailable · Check page ↗5 shared non-person entities · 1 shared topics · similarity 0.936
machine-extracted · confidence unavailable · Check page ↗4 shared non-person entities · 1 shared topics · similarity 0.936
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000180188
Cover letter from ATC Associates to the NYC Board of Education submitting indoor air quality measurements for 90 Trinity Place in April 2002.
5 shared non-person entities · 1 shared topics · similarity 0.936
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000177847
Cover letter and report detailing indoor air quality measurements collected at PS 234M on January 24, 2002, to evaluate building contamination.
5 shared non-person entities · 1 shared topics · similarity 0.935
machine-extracted · confidence unavailable · Check page ↗5 shared non-person entities · 1 shared topics · similarity 0.935
machine-extracted · confidence unavailable · Check page ↗1 shared non-person entities · similarity 0.935
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000149798
Generic form or header page from the Department of Environmental Protection regarding general World Trade Center notices and requests.
Similarity score 0.954 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000161615
Document listing examples of World Trade Center evidence and areas of focus for preservation efforts.
Similarity score 0.953 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000104027
Summary of ambient air sampling and visual observations at 105 Duane Street following the WTC collapse.
Similarity score 0.950 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Similarity score 0.950 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Similarity score 0.947 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000125845
Draft fact sheet from DOH and DEP addressing tenant concerns regarding asbestos fibers at 105 Duane Street.
Similarity score 0.947 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000177887
Letter and report detailing real-time indoor air quality monitoring conducted at the school in December.
Similar indexed content
Similar indexed content
Similar indexed content
Similar indexed content
Similar indexed content