Indoor air quality field report, PS 89M, Jan 17 2002

Machine-extracted title · confidence 95%

Field report documenting indoor air quality measurements including temperature, humidity, and TVOCs at PS 89M on January 17, 2002.

NYC-WTC_000174709–000174713
Page image
Scanned page image, NYC-WTC_000174711
OCR text

OCR status: ocr · source: ours

NYC 9/11 Public Portal Document CONFIDENTIAL, SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008 CITY_21MC100_ 014659989 TIME 8:55 LOCATION Location Hall by 419 Stain# 1 430 426 Hall by 4o 415 408 406 404 M89 Occup. - 2 ATC ASSOCIATES, INC. INDOOR AIR QUALITY FIELD REPORT DATE 1/17/02 _PROJECT NO. Temperature ("F) Relative Humidity (%) Carbon Dioxide (ppш) 71.2 21.0 499 71.3 20.9 491 71.4 20.7 449 71.4 20:7 465 70.7 20.9 460 7018 20. 6 449 71.8 21.3 74.1 2/.7 460 572 73.6 20.6 455 401 (11A11) Guideline levels ASHRAE/AIHA/EPA 73.0 68-75°F/winter 73-79°F/summer 20.4 30-60% 460 Ouidoor level + 700 ppm Comments: Carbon Monoxide (ppu) 0 9 ppm The assessed location(s) () Does () Does not meet established indoor air quality guidelines. Signature: Ji Chor Dale: 1/11/02 NYC-WTC_000174711 Page 3 of 5. 19125-297 Respirable Particulates(ug/m) 25 23 23 28 27 24 19 26 22 25 65 ug/m 24-hour average TVOCS (Ppm) 0 1 ppm

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000174711Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000177950

Field report containing temperature, humidity, and gas readings from indoor air quality testing at P.S. 150M.

Similar indexed content

Compare copies and versions →