Phase Contrast Microscopy (PCM) Fiber Results
35052-0000-00007; New York City Law Department; 100 Church Street/OSHA
Flow Air Fiber Fibers
SclLab Client Date Rate Duration Filtered Density Cone.
Fields Fibers TWA
Sample # Sample # / Location Collected (liters/min.) (min.) (liters) (Fibers/mm^ ) (Fibers/cc)
01 GS-0218-OSHA-0624 2/18/02 2 300 600 100 8 10.19 0.007
Ruben Reyes
02 GS-0218-OSHA-0411 2/18/02 2 300 600 100 2 2.55 <0.004
Manolo Alles
03 GS-0218-OSHA-0625 2/18/02 2 330 660 100 12 15.29 0.009
Ruben Reyes
04 GS-0218-OSHA-0412 2/18/02 2 330 660 100 10 12.74 0.007
Manolo Alles
05 GS-0218-OSHA-B1 2/18/02 0 0 0 100 0.5 0.64
Field Blank Footnotes: /
06 GS-0218-OSHA-B2 2/18/02 0 0 0 100 0.5 0.64
Field Blank Footnotes: 1
Reporting Notes:
(1) Fibers/cc cannot be Cl lai 3)W le.
Analyzed by: Devin Ahyee _____________ Date f 2/19/02
Samples analyzed by NIOSH 7400(A) Method. Issue #2, 8/1 ®94; Limit of Detection= 5.5 fibers per 100 fields or 7 fibers/mm2: This report relates ONLY to the sample analysis expressed as fibers/sq mm of filter area; ND=No fibers observed: NA= Not
Analyzed; Walton-Beckett graticle field area = 0.00785 mm2: TWA = 8 Hr TWA calculation assumes zero exposure for remainder of 8 hr period not sampled; Upper 95% Confidence limit (Employers Compliance Test)- Calculated as a one sided UCL to
determine 95% certainty of compliance with the 0.01 fiber/cc standard; Estimated relative standard deviation; Intralab Sr=0.405, Interlab Sr=0.45, New York samples (NYSDOH ELAP Lab # 11480); National Institute of Standards and Technology
Accreditation requirements mandate that this report must not be reproduced except in full without the approval of the laboratory, AIHA # 102843.