Material Safety Data Sheet, Garman Company, March 1992

Machine-extracted title · confidence 95%

Safety data sheet listing hazardous compounds including propane and isobutane for a chemical product manufactured in 1992.

NYC-WTC_000169028–000169029

Folder label: “7 World Trade Center Blue Prints Haz Mat Info Fire Reports Fire Prevention Records

Page image
Scanned page image, NYC-WTC_000169028
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

e_A R M A N__ COMPANY / V A P C 0 C_h_e_m_i_c_a_X s

1702 Chase Dr. Fenton, MO 63026 314-343-5155

MATERIAL SAFETY DATA SHEET

PAGE 1

SECTION 1 IDENTITY

GARMAN COMPANY TRADE NAME: No Sweat 1702 Chase Dr. DATE PREPARED: 03/12/92 Fenton, MO 63026 COMPANY PHONE: 314-343-5155 EMERGENCY TELEPHONE NUMBER: 1-800-255-3924

SECTION 2 H A_Z_A_R_p_O_y_S__ I_N 6_R E D I E N T S

HAZARDOUS COMPOUNDS CAS 7. OSHA PEL ACeiH TLV Methylene Chloride* 75-09-2 £0-75 500 ppm 50 pom Propane 74-9S-6 1000 ppm 1000 ppm Isobutane 75-28-5 Not Est. 800 ppm 30 B Storage Code: Level #1 N. F. P, A. : Health - 2 Reactivity - 0 Fire 1 * Subject to SARA Title III, Section 313

S_E_C_T_I_g_N__ 3 C_H_E_M_I_C_A_L__ &__ P_H_Y_S_I_C_A_L__ D_A_T_A

ing Point............... NA Speci fic Gravity<H20=l)@25C..1.25 >._.por Pressure <psig € 25C. . . 80 Vapor Density........... . >1 Evaprtn RateCButyl Acetate=l) <1 pH Information............................. .. NA Solubility in Water Insoluble Reactivity in Water...................... NA Appearence ?< Odor: Percent Volatiles............................. 857. White Coating - Sweat Chlorinated Odor

S_E_C_T_I_g_N__ 4 __ 5$__ E_x_p_L_g_s_i_g_N__ b_^_2_A_R_E___P_a_i_a

Flame Projection: 16" Flash Point <TCC>:NA Flammable Limits: LEL: NA / UEL: NA Extinguishing Media: Foam, C02, Dry Chemical, Halon

Fire 8< Explosion Hazards: Exposure to temperatures over 120 degrees F. may cause bursting or venting. Heat or fire may cause hazardous fumes: Carbon Monoxide, Phosgene, Chlorine, or Hydrogen Chloride

Firefighting Procedures: Wear self-contained breathing apparatus with full facepiece operated in pressure-demand and full body protective clothing when fighting fires.

SECTION 5 H_A_Z_A_R_p_O_y_S__ R_E_A_C_T_I_y_I_T_Y Stabilty: Stable Hazardous Polymerization: Cannot occur npatability: Oxidizing materials .omposition: Open flames can cause hydrogen chloride, phosgene, chlorine

NA - NOT APPLICABLE NDA - NO DATA AVAILABLE

NYC-WTC_000169028

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000169028Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000169006 · Box FDNY

Memo instructing administrative units to file hazardous substance disclosure forms and MSDSs for a specific occupancy.

Filed in the same folder