A M* 6*02 NiFE MATERIAL SAFETY DATA SHEETS NICKEL CADMIUM INDUSTRIAL BATTERIES

tA»T NiFi ItM! For Chemical Inwrgoncy 711 Induiwlat alyd, Spill, leek, Fife, Ixpaiure or Accident VoldMJi ■ CAll CHIMTMCC - bay or Nifiht 1. Phon* #91i*2f7-imi e00U24-$300 • •I ■ Fox $12'247-WB6

HMIS (totlnflo; 3 HEALTH I Flommablllfy 3 Htjcctlvlfy

L HEALTH HAZARD JNFORMATJON of OvoroxpoeVr* Eyo tHodu Confoct with electrolyte *olutlon Inalde battery causes very ropid, severe damoge. Extremely corrosive io eye tissue*. Moy msult In pormonent blindness. Confoct with okksl may cause minor Irrtiotlon. Jkln Contoet with electrolyte solution Inside battery may cause lerloui burns to skin tissues Contact with nickel moy cause skin sensitization, resulting In chronic aezerno er nickel Itch. . tngMtlon: Ingestion of electrolyte *olutlon causes tissue damage to throat area and goslro/ respiratory tract. Ingestlpn or nickel oxide causes nausea and giddiness, ' lnhafo1l<?nt During acflvollon proeodurec mist gencroted moy cause varying degreoi of Irrtfatfon of the nosal fhucous membranes ond respiratory troef. tissues, Mey vary Ironi mild Irritation of nasal mucous membrane* to domege of lung tliiuei proper. Inhalation of cadmium oxide may eau»e dry throof. cough, heodache, vamltfhg, chest pain, chtffs, exeeulvo overexposure moy result In pulmonary emphysema, corpulmonoie. Corclnojonldtyi Nickel and Cadmium hove been reported os carcinogenic in onimol tests.

2. IMiRGENCY FIRST AID ' Bottory Sloctrolyloi Iyo .Contact) Fiuih with plonfy al water for o( load 15 mlnu)»», G»< Immodlota madlco) ott«n((on. ' Skin Contact) Remove oontamlnated clothina and flush affsetad areas with plenty of water for at Jeast 18 mlnuias. InfMtton) be not induce vomiting. Ollu’e by giving woter. 11 ovotloble give leveral glauet of milk. Got Immedlote modlcoi attention. Do not give onything by mouth 10 on uncouteteu* person. InJ^aloHont Remove to fresh olr. Give oxygon or artificial recptrOflon If needed, Get Immediate m'edlco! . attention. Nfckol) tkio COhiacti Wmh with cold woter and loap.

3. SPECIAL PROTECTION INFORMATION Perform octlvoflon procedures In e well venHiated areo. flattery operaring areas must be well venfflofed to remove normot gases generated. Respiratory Protection! Use NIOSH approved mist respirator if necessary during activation and actual usage. (ye Protection! Use splosh goggles Or foes shield whenever handling a battery. Hand Pretectloni If exposed to electrolyte solution, or dried salts, use any woter • Insolubjjjon • permeoble glove, Le„ synthetic rubber. 00 NOT use feather ar wool. Other Protective Bqulpmonti Rubber Soots, rubber apron or rolawear dr equivalent if exposed to electrolyte solution, _______________________ ______________________ '

4, REACTIVITY DATA atoHe under normol Condition*. CAUnONi NIVIR ACnVATB OR WR OW WITH ACID. / InceneetnfafiMeet Aluminum, Fine, tin end other nonferrout metoU. odd, chlortnolec! and aromotk hydrocorhont. . nifrooorbone, holocarbone, TrlcWoroofhylene will react with electrolyte solution to form dJchlorocetylene yrhlch t I* sp«ntene<4»ly eembustlble. Hexardou* DecempatHlon Preductii Nickel oxide, Cadmium, cadmium oxide, end potassium hydroxide. Note thot normal reoctlons inside battery llbercfe tiammoble hydrogen gas. Do net seal battery from etmospf^ere. • V i Kozordout Pofymeriiatlon will not occur. 4

NYC-WTC_000166456

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000166456Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

Nickel Cadmium Industrial Battery MSDS, n.d. · Box FDNY

NYC-WTC_000169124

Material Safety Data Sheet for Nickel Cadmium industrial batteries warning of electrolyte hazards and providing emergency spill response instructions.

5 shared non-person entities · 1 shared topics · similarity 0.960

machine-extracted · confidence unavailable · Check page ↗

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000169124 · Box FDNY

Material Safety Data Sheet for Nickel Cadmium industrial batteries warning of electrolyte hazards and providing emergency spill response instructions.

Similar indexed content

NYC-WTC_000169103 · Box FDNY

Material Safety Data Sheet for Yuasa-Exide lead acid batteries identifying hazardous ingredients and providing emergency response contact details.

Similar indexed content

NYC-WTC_000166435 · Box 7FDNY

Material Safety Data Sheet for a lead battery product from Yuasa-Exide Inc. with emergency contact info.

Similar indexed content

NYC-WTC_000166386 · Box 7FDNY

Material Safety Data Sheet identifying methyl and ethyl alcohol as ingredients in a solvent product.

Similar indexed content

NYC-WTC_000169072 · Box FDNY

Material Safety Data Sheet for denatured solvent alcohol detailing composition of methyl and ethyl alcohol with NFPA hazard ratings.

Similar indexed content

Compare copies and versions →