Convention center drainage connection approval, Apr 1985

Machine-extracted title · confidence 95%

Memo approving proposed PVC drainage connections from the New York Exposition and Convention Center to the city storm sewer.

NYC-WTC_000165035–000165037

Folder label: “N.Y. EXPOSITION & CONVENTION CENTER SANITARY HOUSE CONNECTIONS & STORM CONNECTIONS”

Page image
Scanned page image, NYC-WTC_000165037
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

March 6, 1985 Syska & Hennessy

New York Convention Center Storm Sewer

References: A. Perma-Loc - PVC Sewer/Drain Pipe - Johns-Manville

B. Handbook of PVC Pipe - Design & Construction 1. Pipe: 24 in. Perma-Loc Series 46 2. Soil: Wc = 120 Ib/cu. ft

Soil type - pipe bedding material'

A - Clas-s III, GM/ GC, SM,.SC _ 3^-, ■ i superioad:-’; 6Wib/sq/ft'; ' '■ ' .

■ ’ . ^Equivalent height 'ho = 6£02_lb/s£;_^ ■= 5.0 ff - 120 Ib/cu.tt ■ 4'. Pipe, cover - see sketch

.Min. hl =3.66 -ft. Max. hl' = '6.71-ft

5.~ -Vertical_load on plastic pipe (prism load) W ='Wc X H-+ Be Ib/ft ' , ” .

H =-\6,71 + 5.0 = l-1.71--ft, say 12.0 ft . W -=• ’ 3067_ Ib/ft'- ■See_ _Ref. A table on page 4 -■ ' _ . - Soil pressure P = Wc x H = 120 X 12 = 1440’ Ib/ft = 10 Ib/sq in.

6. Pipe deflection - modified "IDWA Deflection Formula" - Ref. B, page 144, Equation No. 25:

- DX X K X P- X 100 I D 0.149 F 4- 0.061 El I AY -

D2 = lag factor Ref. B, table 26 ' K = bedding factor It

. El =soii stiffness 11

* F = pipe stiffness Ref. A - ■ - TTy - -

NYC-WTC_000165037

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000165037Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

DEP comments on drainage plans, Oct 1983 · Box DEP Box 44

NYC-WTC_000165844

Department of Environmental Protection review comments on 30% plan drawings requesting key plans, legends, and distance measurements.

1 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.920

machine-extracted · confidence unavailable · Check page ↗

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000165030 · Box DEP Box 44

Fragmented document text related to sanitary house and storm connections for the New York Exposition and Convention Center.

Filed in the same folder

NYC-WTC_000165031 · Box DEP Box 44

Fragmented document text related to sanitary house and storm connections for the New York Exposition and Convention Center.

Filed in the same folder

NYC-WTC_000165033 · Box DEP Box 44

Inter-departmental memorandum requesting hydraulic review of a sanitary house connection drawing for the New York Exposition and Convention Center.

Filed in the same folder

Compare copies and versions →