sam'e sampling event, however, based on the data received it appears
that
there were no outdoor samples collected for comparison. Using an
approach
that is less desired than the standard practice, the following
conclusions
can be drawn from the data. Although there are no specific standards,
the
general rule of thumb for interpreting mold data usually considers
concentrations greater than 10,000 CFU/in2 to be the low end of the
spectrum
for beginning additional mold investigation, and concentrations greater
than
100,000 to signify "mold contamination". The concentrations for each
individual species, as well as the total sum for all species was well
below
10,000 CFU/in2. In addition, the fungi species observed are the most
frequent species identified and are ubiquitous in the environment,
both
outdoors and indoors. This leads to an overall conclusion that the
concentration and species of mold present are typical of an indoor
environment. In general, mold contamination is identified by finding
visible mold growth that covers an area greater than 1 square meter.
More
information can be obtained from the American Industrial Hygiene
Association
at http://WWW.aiha.org/GovernmentAffairs-PR/html/oomold.htm .
Bacteria
The interpretation of the bacteria results has the same limitations as
discussed above for mold, namely that indoor concentrations should be
compared to outdoor concentrations. There is less information about
indoor
concentrations of bacteria than there is for mold, however one report
http://WWW. atsdr.cdc.gov/HAC/PHA/franklinfungi/ief_pl.html from the
Agency
for Toxic Substances and Disease Registry (ATSDR) reports that
concentrations of Bacillus at 1,000 CFU/in2 and Staphylococcus at
2,400
CFU/in2 are low and most likely are a normal part of the bacterial
load.
The concentrations reported from 114 Liberty are much lower than these
values. Therefore, even though there was not an appropriate outdoor
sample
collected for comparison, it can be concluded that the bacterial
concentrations reported from the one indoor sample that was collected
are
typical of an indoor environment.
If you require any additional information please contact Michael
Gilsenan of
NYCDEP
at 718 595-4418.
Sincerely,
Chris D'Andrea, MS, CIH