HVAC ventilation system inspection checklist guidance, Dec 2002

Machine-extracted title · confidence 85%

EPA forwards revised HVAC cleaning checklist and proposes meeting to brief DEP staff and contractors on implementation procedures.

NYC-WTC_000162671–000162687

Folder label: “E-mails 2002 M. Gilsenan

Page image
Scanned page image, NYC-WTC_000162686
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Guidance for Ventilation System Evaluation Form Page 6 of?

type of material from which the passive shaft/duct is constructed (e.g., metal, fibrous glass lined metal, masonry, fibrous glass board, flex duct, wood). If more than one type of material is present, circle all that apply.

Accessible in-line fire dampers - roughly estimate the number of fire dampers located in the supply air outlets or exhaust air inlets of the shaft. If the fire dampers are completely inaccessible, the estimated quantity should be listed as “unknown”. If the fire dampers are not present, the estimated quantity is zero. Indicate the number of locations where the fire dampers were accessed for inspection in the space provided.

Other components-use this space to describe any other component not already included on the form that is part of the passive shaft-duct structure.

Other information - use this space to indicate any other information deemed relevant to documenting the condition of the passive shaft/duct.

General impression - this space is for the HVAC Evaluator’s general impression of whether or not cleaning is indicated based on the presence of WTC dust. The HVAC Evaluator should note any other comments that are deemed relevant to the determination of WTC dust or comments on conditions that would likely impact the scope or feasibility of cleaning.

2.5 Other Ventilation System

This form is for any ventilation system equipment or configuration that does not appear to conform to any of the types 2.1 through 2.4.

Perform the most vigorous visual inspection possible. Minimum inspection equipment should include screwdrivers, a utility knife (for opening panels, diffusers, grilles, etc. that are painted or caulked in place), cordless drill, hole plugs, telescoping mirror, flashlight, and portable borescope. In addition, the HVAC Evaluator should attempt to penetrate visible dust to determine if a WTC layer is present.

When a ventilation system component is accessed for inspection, indicate whether or not surface dust/debris is present, and whether or not suspect WTC dust is present in the second and third columns, respectively.

Associated Mechanical Room - indicate if there is a mechanical room associated with the other ventilation system, e.g., one or more components located in the mechanical room.

System components - please list all components of the other ventilation system. If the listed component is located, but is not accessible for inspection, indicate “inaccessible” (I) in the right­ hand column.

Other information - use this space to indicate any other information deemed relevant to documenting the condition of the other ventilation system.

NYC-WTC_000162686

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000162686Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →