NYC 9/11 Public Portal Document
FROM : L+D LOMBARDI FAX NO. : 1-631-205-9268 Apr'. 28 2002 11:04AM P5
226 East 45th Street
WKP 10th Floor
New York, NY 10017
Tel; (212) 922-0669
LABORATORIES, INC Fax: (212) 922-0630
AIR SAMPLE ANALYSIS REPORT
PHASE CONTRAST MICROSCOPY
CUENT; WARREN & PANZER ENGINEERS. P C. TUftNArtOUNO TIME 24Hft8
WKP FILE # 501-01 SAMPLE DATE <127/02
WKP LOGI.D.# NO2O42O.N02O421 .NO2O422 RECerVED DATE iflim
coniraci#: WTC AR2 ANALYSIS DATE VZ7K32
REPORT DATE d2ei02
CLIENT JOB: NYC Department of Environmental Protection
CLIENT JOB#: 1079.01.01
LOCATION S.W. Area/ Site Map
ANALYSIS: AIRBORNE FIBER COUNTING, PHASE CONTRAST MICROSCOPY, NIOSH 7400. NIOSH PAT Lab NO. 07186; NY
COLLECTION DEVICE 2S mm MCE Filter Cassette; Collection Area = 385 mm;
SAMPLE WERE COLLECTED BY; Warren and Panzer Engineers, P C.
SUMMARY OF ANALYSIS
CUENT FIBERS/ FIBERS/
SAMPLE » Site# SAMPLE LOCATION Vol. eq rnm oc
1079.01.01 001 27 Gateway Plaza Park Area 675 0.00 0.004
002 31 South End Ave. and Albany Street 675 0.00 0.004
003 32 West Street and Albany Place 675 0.00 0.004
004 33A Rector Place by the Park Place 675 0.00 O.004
006 34 W. Thames Street - Along Waterfront 675 0.00 0.004
006 37 West of Third Plaoe 67S 000 0.004
007 a West Street and Warren Street 67S 0.00 0.004
006 4 River Terrace and Chambers Street 675 0.00 0.004
009 SA River Terrace Park Area Between Park Place and Warren Street 675 000 0.004
010 e River Terrace and Park Place West 675 0.00 0.004
011 17 River Terrace and Veeey 675 0.00 0,004
012 7 Warren Street and North End Avenue 6^ 5.10 0.004
013 10 North End Avenue Park place West 675 0.00 0.004
014 20 Trinity Place and Thames Street 675 0.00 0.004
015 21 Fulton and Church Street 675 0.00 0.004
016 2CA Vesey Street and West Broadway 075 0.00 0.004
017 16 Park plaoe and Church Street STS 0.00 0.004
018 12 Murray Street and Church Street 675 0.00 0,004
019 15 Park Plaoe and Greenwich Street 675 0.00 <0.004
020 11 Murray Street and Greenwich Street 675 0.00 0.004
021 Field Blank 0.00
Field Blank 0.00
NOTES: 1 S.5 fibers/100 fields was used to calculate the Smit of detection (LOO). Results below the LOO have no statistical validity.
2. Samples were not collected by WKP Laboratores. inc.
3. The Federal EPA Clearance Critical following an asbestos abatement project is 0.010 fibers/cc
4. PCM air samples will be disposed of after 3 months unless otherwise directed by client in writing.
Chris Pepino J^uit JCrnibenti
laboratory ANALYSI I ABORaTORY director