NYC 9/11 Public Portal Document
212 949 1273 P .oz
Apr--23-O2 1O:26A
22BEa6t45VlStr»et
WKP 10th Root ,
New YbfKNYrtOOl?
Tei: (jnajWfSees
LABORATORIES, INC
AIR SAMPLE ANALYSIS REPORT
Fax:(2i2)g22-oa3o
PHASE CONTRAST MICROSCOPY
CLIENT; WARREN & PANZER ENGINEERS, P C
turnaround time 24HRS
WXP FILE # 501-01
SAMPLE DATE </22/J002
WKP LOG 1.0. # N0204192. N02Q4183. and NQ204194
ReCGIVEO DATE <«M002
Conlraot #; WTCAR2
ANALYSIS DATE 4/23/2002
REPORT DAlt 4/2a«QO2
CLIENT JOB. NYC Department of Environmental Protection
CLIENT JOB «. 107901.01
LOCATION S.W Area/ Site Map
ANALYSIS; AIRBORNE FIBER COUNTING. PHASE CONTRAST MICROSCOPY, NIOSH 7400 NIOSH PAT Lab NO 07186; NY
COLLECTION DEVICE 25 mm MCE Filter Cassette; Collectien Area = 385 sq mm:
SAMPLE WERE COLLECTED BY: Benny Giambrone. J. Garcia and Festy Oemwegie
SUMMARY OF ANALYSIS
CLIENT FIBERS/ FIBERS/
SAMPLE* Sile« SAMPLE LOCATION Vol, sq mm cc
1078.01,01 001 27 Gateway Plaza Partt Area 675 0.00 <0.004
002 . 31 South End Ave. and Albany Street 675 0.00 <0.004
003 32 West Street and Albany Plaoe 675 0.00 <0.004
004 33A Rector Place by the Park Place 675 3,80 <0.004
005 34 W. Thames Street ■ Along Waterfront 675 0.00 <0.004
006 37 West ol Third Place 675 0.00 <0.004
007 8 West Street and Warren Street 675 2.50 <0.004
□08 4 River Terrace and Chambers Street 675 3.80 <0.004
009 6A River Terrace Park Area Between Park Place and Warren Street 675 0.00 <0.004
01O 9 River Terrace end Park Place West 675 3.80 <0.004
011 17 River Terrace and Vesey <0 004
Warren Street and North End Avenue
•?? 0.00
□ 12 7 675 0.00 <0.004
013 10 North End Avenue Park place West <0.004
675 0.00
014 29 Trinity Place and Thames Street 675 <0.004
0.00
015 21 Fulton and Church SIreel <0.004
675 0.00
010 20A Vesey Street and West Broadway 675 <0.004
0.00
017 16 Park plaoe and Church Street <0.004
675 0.00
016 12 Murray SIreel and Church Street 0.007
67S 12.70
019 15 Park Place and Greenwich Street 675 <0.004
0.00
020 11 Murray Street and Greenwich Street <0.004
675 0.00
021 Field Blank 0.00
022 Field Blank 0.00
NOTES. 1. 5.6 fibers/100 fields was used to calculate the limit of detection (LOD]. Results below the LOO have no statistical validity.
2. Samples were not collected by WKP Laboratories, Inc.
3. The Federal ERA Clearance Critical following an asbestos abatement project is 0.010 fibers/cc
4. PCM air samples will be disposed of after 3 months unless otnerwise directed by client in writing.
Chris Pepino
LABORArOnV analyst
laboratory director