NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 42/WTC- Air Data
Document / 3 pages

WKP Air Sample Analysis Report for WTC Sampling, Apr 2002

Machine-extracted title · confidence 95%

Phase contrast microscopy report for airborne fiber counting at the World Trade Center site dated April 7, 2002.

NYC-WTC_000161783–000161785

Folder label: “WTC- Air Data

Page image
Scanned page image, NYC-WTC_000161784
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

fiPR-03-2002 15:44 BANHM LABORATORY UNIT P.06 J

228 East 45tn Street

WKP LABORATORIES. IMC 10lh Floor New York. NY 10017 Tet: (212) 972-0689 Far (212) 922-0630 AIR SAMPLE ANALYSIS REPORT PHASE CONTRAST MICROSCOPY

CLiEffr: warren & PANZER ENGINEERS. P.C. TURNAROUND TIME 24HRS WKP file# SOI 451 SAMPLE DATE 44502 WKPLO3ID« NQHM3D RECEIVE DATE 4ISO2 Contract WTCAR2 ANALYSIS DATE 4SO2 REPORT DATE 4«O2 CLIENT JOB; NYC Department or Environment Prateetion

CLIENT JOS *; 1079.01.01

LOCATION

ANALYSIS; AIRBORNE FIBER COUNTING. PHASE CONTRAST MICROSCOPY, NIOSH 7400. NlOSH PAT Lab NO. 07106; NY STATE ELAP Lab NO. 11251. COLLECTION DEVICE: Csseette; Colleetlsn Area = 3BS sq mm; Field Area = 0.00785 sq mm.

SAMPLE WERE COLLECTED BY: Benny Ciambfone

SUMMARY OF analysis CLIENT VOLUME FIBERS/ FIBERS/ sample* Site* SAM.OLE LOCATION (UTSRS) $0 mm ee 1079.0101 001 6 WmS Street and Warren Street 675 3500 <0.004 032 4 River Terrace and Chambers Street 675 0.000 <0.004 OCO 7 Warren Street and North End Avenue 675 7.000 0.006 004 10 North Ertd Avenue Park pIsM W«a 675 5.000 0.004 005 17 River Terrace and Vesey 675 1.000 <0.004 006 6a River Terrace Pjix Area Between Park Ptase end Warren Street 675 1.000 <0.004 007 9 River Terrace end Park Place Wea 675 2600 <0004 w

NOTES: L liters 00 Fields was used to calculaui the limit of detection (LODj. Results below the LOO have no statUtieai validity. 2. Samples were not collected by WKP Laboratories, Inc. 3, The Federal EPA Clearanoe Criticai fodowing an asbestos ebatement project Is 0.010 fbers/oc. 4. PCM eir samples will be disposed of after 3 months unless ottwwise diftscted by client in wntirg.

p.M._______ _ XwttfZityAwg ______ LABORATORY analyst laboratory DIRECTOR

APR-06-2002 12:21 1 631 205 9269 977: P.04

NYC-WTC_000161784

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000161784Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

WKP Laboratories inter-company invoice, April 2002 · Box DEP Box 42

NYC-WTC_000161740

Laboratory invoice for PCM and PLM analysis services with sample receipt date April 8, 2002, documenting analysis turnaround options and quantities for WTC-related testing.

9 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.948

machine-extracted · confidence unavailable · Check page ↗

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000161610 · Box DEP Box 42

A single-page air quality data sheet from the Department of Environmental Protection regarding the World Trade Center site.

Filed in the same folder