NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 42/WTC- Air Data
Document / 17 pages

Staff list for infrastructure paper preparation

Machine-extracted title · confidence 70%

Document excerpt listing counsel and staff members assigned to a paper on infrastructure related to World Trade Center recovery.

NYC-WTC_000161674–000161690

Folder label: “WTC- Air Data

Page image
Scanned page image, NYC-WTC_000161677
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Any "overload" results should be presumed to be higher than 70 s/mm^ for two reasons. First, "overload" means that there was such an excess of particulate material on the collection device that the laboratory could not even make a reading, meaning there was a high level of all particulates, including asbestos. Second, whenever there were "overload" results from the TEM tests in early days, the corresponding tests at the same location using a light microscope (PCM) were much higher than the PCM levels where asbestos was verifiably over 70 s/mm^. In other words, paired tests looked like this: TEM electron microscope result PCM light microscope result Location A 45 s/mm^ 0.010 f/cc Location B 157 s/mm^ 0.040 f/cc Location C overload 0.080 f/cc

Even if the "overload" results are ignored, then 18% of the 87 tests (16 out of 87) between 9/12/01 and 9/29/01 were over 70 s/mm^ . This is significant. In contrast, in its 10/3/01 press release, EPA claimed that only 6% (27 out of442) air samples IN THE IMMEDIATE VICINITY of Ground Zero were over 70 s/mm^ . ’

Summary of deletions and alterations of the original NYC data The Appendix to this memorandum compares the two different versions of the same NYC ,

Tests above 70 s/mm^ NYC altered 6 of the original test results that showed asbestos over 70 s/mm . NYC altered the data by either deleting the sampling location and accompanying data altogether, claiming that no asbestos was found (below the detection limit), or claiming that there were no TEM tests at the particular location for that day.

"Overload" tests NYC altered 11 of the results that were overloaded. Overload means that there were such "X high levels of asbestos and other particulates in the test device that asbestos could not even I be counted. As discussed earlier, overload samples are presumptive of concentrations over I 70 s/mm^. NYC altered the data by either claiming that no asbestos was found (below the k detection limit), or claiming that there were no TEM tests at the particular location for that J day.

Tests where asbestos found, but below 70 s/mm^ NYC also altered the tests results where asbestos was found in the air, but found at levels lower than 70 s/mm^ . This is highly significant as well, because NYC as well as EPA were claiming that there was no detectable asbestos in most instances. The altered version of the

4

NYC-WTC_000161677

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000161677Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000091539 · Box DEP Box 68

Raw laboratory sequence file listing pesticide compounds and calibration standards processed in late 2001.

Cited alongside this record in an Ask answer

Compare copies and versions →