5 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.980
machine-extracted · confidence unavailable · Check page ↗E-mails R. Avaltroni 2002
Label derived from the City's folder field. The City does not supply document titles.NYC-WTC_000160896–000160911
OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Roof Clean-Up
Application: This procedure utilizes wet methods and careful hygiene protocol for cleaning roofs contaminated with asbestos containing material (ACM). 1. The entire roof shall be considered the work area for entry/access determinations. AU abatement wiU be performed by NYSDOL licensed contractors with NYC DEP certified workers. For non-gravel or stone covered roofs with localized accumulations of visible debris, the clean-up areas shall be specified (“specified area”) by DEP. For gravel/stone covered roof surfaces, the entire roof shaU be included in the specified roof area for clean up. The gravel/stone shaU be taken to a clean-up staging area on the roof and washed. Water shall be collected, filtered, and discharged into the drain/sewer as applicable.
2. A changing area consisting of two adjacent step-off pads located on the roof immediately adjoining the roof entrance/exit. This area shall consist of a clean pad and a change pad. The clean pad shall be adjacent to the building interior access way (or at die point of entry to the roof for exterior access). The change pad shall be adjacent to the contaminated roof areas. Each pad (change pad and clean pad) shall consist of two layers of 10-mil reinforced plastic on the roof/access way surface and shall be large enough to facilitate changing and decontamination as described herein. A minimum of 4’ x 4’ is recommend, though the exact configuration will be specific to the roof.
3. Workers shall first step from the buUding interior (or exterior at the point of entry to the roof) directly onto the clean pad. On the clean pad, each worker shall be double suited with disposable coveralls, plastic booties, gloves, and head coverings. Rubber boots may be used instead of the plastic booties. The boots shall be wet wiped and HEPA vacuumed prior to leaving the roof. Each worker shall wear a minimum of a half-face air-purifying respirator equipped with HEPA cartridges. 4. All penetrations at the roof within 10 feet of the specified roof area included in the clean-up shall be cleaned by wet methods/HEPA vacuum and sealed with 6-mil polyethylene sheeting. 5. Roof cleanup shall begin at the entrance/exit and proceed in a path working away from the entrance/exit. Water shall be the primary engineering control to minimize the potential for fiber release.
6. Roof surfaces shall be wetted and then wet cleaned using wet wiping techniques with water, mops, rags, brushes, etc. HEPA vacuuming may also be used as alternative to or in combination with wet cleaning. 7. Throughout the procedure, all personnel entering or existing the roof shall observe the personal decontamination practices. Attention shall be paid to limiting unnecessary walking on or disturbance of material on the roof. These personal decontamination procedures shall be strictly adhered to, in order to minimize the potential for spreading contamination to the interior of the buildings.
8. Solid nonporous objects, such as metal patio furniture, plant potters, and plastic furniture cushions, shall be wet wiped with damp rags. Wooden objects such as decking shall be HEPA vacuumed, wet wiped, and lightly brushed with a bristle brush utilizing simultaneous misting and local HEPA exhaust. Woven materials shall either be disposed as ACM or bagged and removed off-site for proper laundering in accordance with 29 CFR 1901. 1001. Potted plants with visual contamination should be disposed as ACM waste unless the
Pages Modified to include Addendum 1 & 2 04/13/02 Prepared by PT
NYC-WTC_000160906
OCR can misread numbers and units. Confirm readings against the page image before using them.
Related records
Browse subjects →Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
Same-box records
9 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.978
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000160772
Discussion of contractors performing WTC facade cleanup using wet-soaking and power-washing protocols and potential water use restriction exemptions.
7 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.978
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000160683
Transmission of WTC-related Q and A document to interagency task force with EPA Regional contact information.
8 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.977
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000160748
Correspondence discussing the scheduling of meetings with building owners and the need for legal vetting of compliance issues.
7 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.977
machine-extracted · confidence unavailable · Check page ↗6 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.977
machine-extracted · confidence unavailable · Check page ↗8 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.977
machine-extracted · confidence unavailable · Check page ↗7 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.976
machine-extracted · confidence unavailable · Check page ↗Filed elsewhere
NYC-WTC_000108786
A document listing seven licensed contractors authorized to perform clean-up and abatement work at the World Trade Center site.
10 shared non-person entities · 1 shared topics · similarity 0.986
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000141536
Request outlining DEP procurement and EPA supervision of cleaning and sampling contracts for Lower Manhattan residents.
7 shared non-person entities · 1 shared topics · similarity 0.983
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000141555
Document requesting FEMA mission assignment for indoor air testing and cleaning programs in Lower Manhattan.
6 shared non-person entities · 1 shared topics · similarity 0.982
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000141504
Request detailing residential cleaning, asbestos air testing, and HEPA vacuum distribution programs for Lower Manhattan with cost estimates.
6 shared non-person entities · 1 shared topics · similarity 0.980
machine-extracted · confidence unavailable · Check page ↗More like this page
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Buildings in this record
Machine-extracted building matches; verify each source. Buildings, never households.
- 290 Broadway · 1 pages · confidence 0.15 · verify page 3
Others also read
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000160529
Notice instructing staff to preserve original World Trade Center documents as potential legal evidence and not dispose of them.
Filed in the same folder
NYC-WTC_000160530
DEP memo documenting inconsistent dust control from WTC debris transport trucks affecting school reopening plans.
Filed in the same folder
Filed in the same folder
NYC-WTC_000160536
DEP memo discussing WTC recovery contractor operations, fuel requirements, infrastructure repairs, and school proximity.
Filed in the same folder
NYC-WTC_000160537
Forwarded draft press release from NYC Department of Health regarding WTC environmental and health guidance.
Filed in the same folder